Nabertherm

Nabertherm

ผู้ผลิตเตาเผา เตาหลอม เตาสำหรับทดสอบขี้เถ้า (Ash Content Testing) สำหรับห้องแล็ป และเตาเผา เตาหลอมอุตสาหกรรมสำหรับการผลิตแก้ว เซรามิกส์ พลาสติก โลหะ เป็นต้น สามารถควบคุมอุณหภูมิในช่วง 30-3000 องศาเซลเซียส มีให้เลือกใช้หลากหลายขนาด คลิ๊กด้านล่างเพื่อดูข้อมูลสินค้าเพิ่มเติม Muffle/Preheating/Ashing Furnaces and Accessories
Muffle furnace L 3/12 Muffle furnace L 5/11
Muffle furnace LT 5/12 Muffle furnace L 3/11 Observation hole in the door as additional equipment Over-temperature limiter Gas supply system for non-flammable protective or reactive gas with shutoff valve and flow meter with regulator valve, optionally with magnetic valve Adjustable air inlet integrated in the door The muffle furnaces L 1/12 - LT 40/12 are the right choice for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability. The muffle furnaces come equipped with either a flap door or lift door at no extra charge.
  • Tmax 1100 °C or 1200 °C
  • Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 40/12)
  • Ceramic heating plates with integral heating element which is safeguarded against fumes and splashing, and easy to replace
  • Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
  • Housing made of sheets of textured stainless steel
  • Dual shell housing for low external temperatures and high stability Optional flap door (L) which can be used as work platform or lift door (LT) with hot surface facing away from the operator
  • Adjustable air inlet integrated in door (see illustration)
  • Exhaust air outlet in rear wall of furnace
  • Solid state relays provide for low-noise operation
  • Defined application within the constraints of the operating instructions
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive

Additional equipment

  • Chimney, chimney with fan or catalytic converter (not for L 1)
  • Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and load
  • Protective gas connection to purge with non-flammable protective or reaction gases (not available in combination with chimney, chimney with fan or catalytic converter)
  • Observation hole in the door
  • Manual or automatic gas supply system
  • Process control and documentation via VCD software package for monitoring, documentation and control

Available Model Number ; Flap door : L 3/11, L 5/11, L 9/11, L 15/11, L 24/11, L 40/11, L 1/12, L 3/12, L 5/12, L 9/12, L 15/12, L 24/12, L 40/12

Lift door : LT 3/11, LT 5/11, LT 9/11, LT 15/11, LT 24/11, LT 40/11, LT 3/12, LT 5/12, LT 9/12, LT 15/12,

LT 24/12, LT 40/12

Muffle Furnaces Basic Models

Muffle furnace LE 1/11 Muffle furnace LE 6/11
Over-temperature limiter With their unbeatable price/performance ratio, these compact muffle furnaces are perfect for many applications in the laboratory. Quality features like the dual shell furnace housing of rust-free stainless steel, their compact, lightweight constructions, or the heating elements encased in quartz glass tubes make these models reliable partners for your application.
  • Tmax 1100 °C, working temperature 1050 °C Heating from two sides from heating elements in quartz glass tubes
  • Maintenance-friendly replacement of heating elements and insulation
  • Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
  • Housing made of sheets of textured stainless steel
  • Dual shell housing for low external temperatures and high stability
  • Flap door which can also be used as a work platform
  • Exhaust air outlet in rear wall
  • Solid state relays provide for low-noise operation
  • Compact dimensions and light weight
  • Controller mounted under the door to save space
  • Defined application within the constraints of the operating instructions

Additional equipment

  • Chimney, chimney with fan or catalytic converter (not for L 1)
  • Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and load
  • Protective gas connection to purge with non-flammable protective or reaction gases
  • Manual gas supply system
  • Observation hole in the door

Available Model Number ; LE 1/11, LE 2/11, LE 6/11, LE 14/11

Muffle Furnaces with Brick Insulation and Flap Door or Lift Door

Muffle furnace LT 5/13 Muffle furnace L 9/13
Furnace lining with high-quality lightweight refractory brick insulation Over-temperature limiter Heating elements on support tubes radiating freely into the furnace chamber provide for particularly short heating times for these muffle furnaces. Thanks to their robust lightweight refractory brick insulation, they can reach a maximum working temperature of 1300 °C. These muffle furnaces thus represent an interesting alternative to the familiar L(T) 3/11 models, when you need particularly short heating times or a higher application temperature.
  • Tmax 1300 °C
  • Heating from two sides
  • Heating elements on support tubes ensure free heat radiation and a long service life
  • Multi-layer insulation with robust lightweight refractory bricks in the furnace chamber
  • Housing made of sheets of textured stainless steel
  • Dual shell housing for low external temperatures and stability
  • Optional flap door (L) which can be used as work platform or lift door (LT) with hot surface facing away from the operator
  • Adjustable air inlet in the furnace door
  • Exhaust air outlet in rear wall of furnace
  • Solid state relays provide for low-noise operation
  • Defined application within the constraints of the operating instructions
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive

Additional equipment

  • Chimney, chimney with fan or catalytic converter
  • Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and load
  • Protective gas connection to purge with non-flammable protective or reaction gases
  • Manual or automatic gas supply system
  • Observation hole in the door
  • Process control and documentation via VCD software package for monitoring, documentation and control

Available Model Number ; L, LT 5/13, L, LT 9/13, L, LT 15/13

Muffle Furnaces up to 1400 °C

Muffle furnace L 9/14

Muffle furnace L 15/14

Over-temperature limiter Gas supply system for non-flammable protective or reactive gas with shutoff valve and flow meter with regulator valve, optionally with magnetic valve These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability. Heating elements on support tubes radiating freely into the furnace chamber provide for particularly short heating times and a maximum temperature of 1400 °C. These muffle furnaces are a good alternative to the familiar L(T) ../11 series when higher application temperatures are needed.
  • Tmax 1400 °C
  • Heating from two sides
  • Heating elements on support tubes ensure free heat radiation and a long service life
  • Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
  • Dual shell housing for low external temperatures and high stability
  • Adjustable air inlet integrated in door
  • Exhaust air outlet in rear wall of furnace
  • Solid state relays provide for low-noise operation
  • Defined application within the constraints of the operating instructions
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive

Additional equipment

  • Chimney, chimney with fan or catalytic converter
  • Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and load
  • Protective gas connection to purge with non-flammable protective or reaction gases (not available in combination with chimney, chimney with fan or catalytic converter)
  • Manual or automatic gas supply system
  • Process control and documentation via VCD software package for monitoring, documentation and control

Available Model Number ; L, LT 5/14, L, LT 9/14, L, LT 15/14

Muffle Furnaces with Embedded Heating Elements in the Ceramic Muffle

L 9/11/SKM
Muffle heated from four sides Gas supply system for non-flammable protective or reactive gas with shutoff valve and flow meter with regulator valve, optionally with magnetic valve Over-temperature limiter We particularly recommend the muffle furnace L 9/11/SKM if your application involves aggressive substances. The furnace has a ceramic muffle with embedded heating from four sides. The muffle furnace thus combines a very good temperature uniformity with excellent protection of the heating elements from aggressive atmospheres. Another aspect is the smooth, nearly particle free muffle (furnace door made of fiber insulation), an important quality feature for some ashing processes.
  • Tmax 1100 °C
  • Muffle heated from four sides
  • Furnace chamber with embedded ceramic muffle, high resistance to aggressive gasses and vapours
  • Dual shell housing made of sheets of textured stainless steel
  • Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
  • Optional flap door (L) which can be used as work platform or lift door (LT) with hot surface facing away from the operator
  • Adjustable working air inlet in the door
  • Exhaust air outlet in rear wall of furnace
  • Solid state relays provide for low­noise operation
  • Defined application within the constraints of the operating instructions
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive

Additional equipment

  • Chimney, chimney with fan or catalytic converter
  • Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and load
  • Protective gas connection to purge with non-flammable protective or reaction gases
  • Manual or automation gas supply system
  • Observation hole in the door
  • Process control and documentation via VCD software package for monitoring, documentation and control

Available Model Number ; L 9/11/SKM, LT 9/11/SKM

Ashing Furnaces with Flap Door or Lift Door

Ashing furnace LV 3/11 Ashing furnace LVT 9/11
Air inlet and exhaust flow principle in ashing furnaces Observation hole in the door as additional equipment Over-temperature limiter The ashing furnaces LV 3/11 - LVT 15/11 are especially designed for ashing in the laboratory. A special air intake and exhaust system allows air exchange of more than 6 times per minute. Incoming air is preheated to ensure a good temperature uniformity.
  • Tmax 1100 °C
  • Heating from two sides
  • Ceramic heating plates with integral heating element which is safeguarded against fumes and splashing, and easy to replace
  • Air exchange of more than 6 times per minute
  • Good temperature uniformity due to preheating of incoming air
  • Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
  • Housing made of sheets of textured stainless steel
  • Dual shell housing for low external temperatures and stability
  • Optional flap door (LV) which can be used as work platform or lift door (LVT) with hot surface facing away from the operator
  • Solid state relays provide for low­noise operation
  • Defined application within the constraints of the operating instructions
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive

Additional equipment

  • Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and load
  • Observation hole in the door
  • Process control and documentation via VCD software package for monitoring, documentation and control

Available Model Number ;

Flap door : LV 3/11, LV 5/11, LV 9/11, LV 15/11,

Lift door: LVT 3/11, LVT 5/11, LVT 9/11, LVT15/11

  Ashing Furnaces with Integrated Exhaust Gas Cleaning  
Ashing furnace L 40/11 BO
The ashing furnace L ../11 BO is specially designed for processes in which larger sample quantities have to be incinerated. Fields of application are e.g. the ashing of food, thermal cleaning of injection molding tools or the determination of annealing loss. Another application is the debinding of ceramic products, e.g. after additive production. The ashing furnaces have a passive safety system and integrated exhaust gas post combustion. An exhaust gas fan extracts flue gases from the furnace and simultaneously supplies fresh air to the furnace atmosphere with the result that sufficient oxygen is always available for the incineration process. The incoming air is guided behind the furnace heating and preheated to ensure good temperature uniformity. Exhaust gases are led from the furnace chamber to the integrated post combustion system, where they are postburned and catalytically cleaned. Directly after the incineration process (up to max. 600 °C) a subsequent process up to max. 1100 °C can take place.
  • Tmax 600 °C for the incineration process
  • Tmax 1100 °C for the subsequent process
  • Three-side heating (both sides and bottom)
  • Ceramic heating plates with embedded heating wire
  • Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
  • Dual shell housing made of structured stainless steel provides for low outer temperature and high stability
  • Steel collecting pan protects the bottom insulation
  • Spring-assisted closing of the furnace door (flap door) with mechanical locking against unintentional opening
  • Thermal/catalytic post combustion, integrated in the exhaust channel, up to 600 °C in function
  • Temperature control of post combustion can be set up to 850 °C
  • Monitored exhaust air
  • Inlet-air preheated through the bottom heating plate
  • Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and load
  • Defined application within the constraints of the operating instructions
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive

Additional equipment

  • Process control and documentation via VCD software package for monitoring, documentation and control
Available Model Number ; L 9/11 BO, L 24/11 BO, L 40/11 BO     Weighing Furnace incl. Scale and Software for Determination of Combustion Loss  
Weighing furnace L 9/11/SW
4 scales available for different maximum weights and scaling areas Over-temperature limiter Software for documentation of the temperature curve and combustion loss using a PC This weighing furnace with integrated precision scale and software, was designed especially for combustion loss determination in the laboratory. The determination of combustion loss is necessary, for instance, when analyzing sludges and household garbage, and is also used in a variety of technical processes for the evaluation of results. The difference between the initial total mass and the combustion residue is the combustion loss. During the process, the software included records both the temperature and the weight loss.
  • Tmax 1100 °C or 1200 °C
  • Heating from two sides
  • Ceramic heating plates with integral heating element which is safeguarded against fumes and splashing, and easy to replace
  • Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
  • Dual shell housing made of sheets of textured stainless steel
  • Optional flap door (L) which can be used as work platform or lift door (LT) with hot surface facing away from the operator
  • Adjustable working air inlet in the door
  • Exhaust air outlet in rear wall of furnace
  • Solid state relays provide for low­noise operation
  • Delivery includes base, ceramic plunger with base plate in the furnace lining, precision scale and software package
  • 4 scales available for different maximum weights and scaling ranges
  • Process control and documentation for temperature and combustion loss via VCD software package for monitoring, documentation and control
  • Defined application within the constraints of the operating instructions

Additional equipment

  • Chimney, chimney with fan or catalytic converter
  • Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and load
  • Observation hole in the door

Available Model Number ;

flap door : L 9/11/SW, L 9/12/SW

Lift door : LT 9/11/SW, LT 9/12/SW

Exhaust Systems/Accessories

* Note: If other controller types are used an adapter cable for connection to mains supply has to be ordered separately. The device will be activated by plugging in the socket.

Chimney for connection to an exhaust pipe.

Chimney with fan, to remove

exhaust gas from the furnace better.

The B400 - P480 controllers can be

used to activate the fan

automatically (not for

models L(T) 15.., L 1/12, LE 1/11, LE 2/11).*

Catalytic converter with fan for

removal of organic components from

the exhaust air. Organic components are catalytically oxidized at about 600 °C, broken into carbon dioxide and water vapour. Irritating odors are thus largely eliminated. The B400 - P480 controllers can be used to switch the catalytic converter automatically (not for models L(T) 15.., L 1/12, LE 1/11, LE 2/11).*

Exhaust torch to burn exhaust gases which are generated during the process. The torch is gas-fired and will be operated with propane gas. If a catalytic post combustion cannot be used for the process this torch is recommended.

Square saggar for furnaces LHTC and LHT, Tmax 1600 °C The load is placed in ceramic saggars for optimal utilization of the furnace space. Up to three saggars can be stacked on top of each other in the furnace. Each saggar has cut-outs for better ventilation. The top saggar should be closed with a lid made of ceramics also.

Round saggar (Ø 115 mm) for furnaces LHT/LB, Tmax 1650 °C These saggars are perfectly suited for furnaces LHT/LB. The load is placed in the saggars. Up to three saggars can be stacked on top of each other in order to use the overall furnace chamber.

Additional equipment

  • Base frame on castors (not for assay furnace N 4/13 CUP)
  • Process control and documentation via VCD software package for monitoring, documentation and control

Pit-type furnace with rolling lid

  • For bigger charges we offer pit-type furnaces as assay furnaces

Available Model Number : N 4/13 CUP, N 8/13 CUP, N 25/13 CUP

Chamber Furnaces for Annealing, Hardening and Brazing  

Chamber furnace N 7/H as table-top model

Chamber furnace N 61/H

Working with protective gas boxes for a protective gas atmosphere using a charging cart

To withstand harsh use in the laboratory, e.g. when heat-treating metals, robust insulation with light refractory bricks is necessary. The chamber furnaces N 7/H - N 87/H are a perfect fit to solve this problem. The furnaces can be extended with a variety of accessories, like annealing boxes for operation under protective gas, roller guides, or a cooling station with a quench tank. Even high-performance applications like the annealing of titanium in medical applications can be implemented without the use of expensive and complicated annealing systems.

  • Tmax 1280 °C
  • Deep furnace chamber with three-sides heating: from both side walls and bottom
  • Heating elements on support tubes ensure free heat radiation and a long service life
  • Bottom heating protected by heat-resistant SiC plate
  • Low energy consumption due to multi-layer insulation
  • Exhaust opening in the side of the furnace, or on back wall of chamber furnace N 31/H and higher
  • Base frame included in the delivery, N 7/H - N 17/HR designed as table-top model
  • Parallel guided downward swinging door (user protected from heat radiation)
  • Gas spring dampers provide for easy door opening and closing
  • Defined application within the constraints of the operating instructions
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
Available Model Number: N 7/H, N 11/H, N 11/HR, N 17/HR , N 31/H, N 41/H, N 61/H, N 87/H     Chamber Furnaces with Brick Insulation or Fiber Insulation up to 1400 °C    
Chamber furnace LH 216/12SW with scale to measure weight reduction during annealing Chamber furnace LF 60/14 with fresh air fan to accelerate the cooling times
Chamber furnace LH 30/14 Chamber furnace LH 30/12 with manual lift door

LF furnace design provides for shorter heating and cooling times

The chamber furnaces LH 15/12 - LF 120/14 have been trusted for many years as professional chamber furnaces for the laboratory. These furnaces are available with either a robust insulation of light refractory bricks (LH models) or with a combination insulation of refractory bricks in the corners and low heat storage, quickly cooling fiber material (LF models). With a wide variety of optional equipment, these chamber furnaces can be optimally adapted to your processes.
  • Tmax 1200 °C, 1300 °C, or 1400 °C
  • Dual shell housing with rear ventilation, provides for low shell temperatures
  • High furnace chamber with five-sided heating for very good temperature uniformity
  • Heating elements on support tubes ensure free heat radiation and a long service life
  • Controller mounted on furnace door and removable for comfortable operation
  • Protection of bottom heating and flat stacking surface provided by embedded SiC plate in the floor
  • LH models: multi-layered insulation of light refractory bricks and special backup insulation
  • LF models: high-quality fiber insulation with corner bricks for shorter heating and cooling times. Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2.
  • Door with brick-on-brick seal, hand fitted
  • Short heating times due to high installed power
  • Self-supporting arch for high stability and greatest possible protection against dust
  • Quick lock on door
  • Motor driven exhaust air flap
  • Freely adjustable air inlet integrated in furnace floor
  • Base included
  • Defined application within the constraints of the operating instructions
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive

Additional equipment

  • Parallel swinging door, pivots away from operator, for opening when hot
  • Lift door with electro-mechanic linear drive
  • Separate wall-mounting or floor standing cabinet for switchgear
  • Cooling fan for shorter cycle times
  • Protective gas connection to purge with non-flammable protective or reaction gases
  • Manual or automatic gas supply system
  • Scale to measure weight reduction during annealing
  • Process control and documentation via VCD software package or Nabertherm Control Center (NCC) for monitoring, documentation and control

Available Model Number : LH 15/12, LH 30/12, LH 60/12, LH 120/12, LH 216/12, LH 15/13, LH 30/13, LH 60/13,

LH 120/13, LH 216/13, LH 15/14, LH 30/14, LH 60/14, LH 120/14, LH 216/14 , LF 15/13, LF 30/13, LF 60/13, LF 120/13, LF 15/14, LF 30/14, LF 60/14, LF 120/14

                  High-Temperature Furnaces/Sintering Furnaces   High-Temperature Furnaces with SiC Rod Heating up to 1600 °C  
High-temperature furnace LHTC 08/16 High-temperature furnace LHTCT 01/16
Furnace chamber with high-quality fiber materials and SiC heating rods on both sides of the furnace Saggars with top lid Over-temperature limiter These powerful laboratory muffle furnaces are available for temperatures up to 1400 °C, 1500 °C, 1550 °C or 1600 °C. The durability of the SiC rods in periodic use, in combination with their high heating speed, make these high-temperature furnaces to all-rounders in the laboratory. Heating times of 40 minutes to 1400 °C can be achieved, depending on the furnace model and the conditions of use.
  • Tmax 1400 °C, 1500 °C, 1550 °C or 1600 °C
  • Working temperature 1500 °C (for high-temperature furnaces LHTC ../16), increased wear and tear must be expected in case of working at higher temperatures
  • Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature
  • Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
  • Optional flap door (LHTC) which can be used as work platform or lift door (LHTCT) with hot surface facing away from the operator (High-temperature furnace LHTCT 01/16 only with lift door)
  • Switching system with solid-state-relays, power tuned to the SiC rods
  • Easy replacement of heating rods
  • Adjustable air inlet opening, exhaust air opening in the roof
  • Defined application within the constraints of the operating instructions
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive

Additional equipment

  • Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and load
  • Square saggar for charging of up to three layers
  • Lid for top saggar
  • Manual or automatic gas supply system
  • Process control and documentation via VCD software package for monitoring, documentation and control
Available Model Number : LHTC(T) 03/14, LHTC(T) 08/14, LHTC(T) 03/15, LHTC(T) 08/15, LHTCT 01/16, LHTC(T) 03/16, LHTC(T) 08/16   High-Temperature Furnaces with MoSi2 Heating Elements up to 1800 °C  
High-temperature furnace LHT 01/17 D High-temperature furnace LHT 03/17 D
Saggars with top lid Over-temperature limiter Designed as tabletop models, these compact high-temperature furnaces have a variety of advantages. The first-class workmanship using high-quality materials, combined with ease of operation, make these furnaces all-rounders in research and the laboratory. These high-temperature furnaces are also perfectly suited for the sintering of technical ceramics, such as zirconium oxide dental bridges.
  • Tmax 1600 °C, 1750 °C, or 1800 °C
  • High-quality molybdenum disilicide heating elements
  • Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature
  • Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
  • Compact design with lift door, opening upwards
  • Adjustable air inlet
  • Exhaust air opening in the roof
  • Type B thermocouple
  • Defined application within the constraints of the operating instructions
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive

Additional equipment

  • Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and load
  • Square saggar for charging of up to three layers
  • Protective gas connection to purge with non-flammable protective or reaction gases
  • Manual or automatic gas supply system
  • Process control and documentation via VCD software package for monitoring, documentation and control
   

Available Model Number : LHT 02/16, LHT 04/16, LHT 08/16, LHT 01/17 D, LHT 03/17 D, LHT 02/17, LHT 04/17,

LHT 08/17, LHT 02/18, LHT 04/18, LHT 08/18

High-Temperature Bottom Loading Furnaces up to 1700 °C

,
LHT 16/17 LB High-temperature furnace LHT 02/17 LB with a set of saggars
Electrically driven lift-bottom Saggar The motor-driven lifting table significantly simplifies the charging of the high-temperature furnaces LHT/LB. The heating all around the cylindrical furnace chamber provides for an opitimal temperature uniformity. For the tabletop models LHT 01/17 LB and LHT 02/17 LB the charge can be placed in charge saggars made of technical ceramics. Up to three charge saggars can be stacked on top of each other resulting in a high productivity. Due to its volume the high-temperature furnace LHT 16/17 LB can also be used for applications in production.
  • Tmax 1650 °C, 1700 °C (LHT 16/17 LB)
  • High-quality heating elements made of molybdenum disilicide offer best possible protection against chemical interaction between charge and heating elements
  • Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
  • Outstanding temperature uniformity due to all-round furnace chamber heating
  • Furnace chamber with a volume of 1, 2 or 16 liters, table with large floor space
  • Precise, motorized toothed belt drive of the table with button operation
  • Appealing, dual shell stainless steel housing
  • Exhaust air vent in the roof
  • Type S thermocouple
  • Defined application within the constraints of the operating instructions
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive

Additional equipment

  • Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and load
  • Stackable saggars for loading in up to two or three levels, depending on model
  • Protective gas connection to purge with non-flammable protective or reaction gases
  • Manual or automatic gas supply system
  • Adjustable air inlet through the floor
  • Process control and documentation via VCD software package for monitoring, documentation and control
  Available Model Number : LHT 01/17 LB, LHT 02/17 LB, LHT 16/17 LB High-Temperature Furnaces with Scale for Determination of Combustion Loss and Thermogravimetric Analysis (TGA)

High-temperature furnace LHT 04/16 SW with scale for measuring weight reduction during annealing and with gas supply system

Software for documentation of the temperature curve and combustion loss using a PC

These high-temperature furnaces were specially developed to determine combustion loss during annealing and for thermogravimetric analysis (TGA) in the lab. The complete system consists of the high-temperature furnace for 1600 °C or 1750 °C, a table frame, precision scale with feedthroughs into the furnace and powerful software for recording both the temperature curve and the weight loss over time.

  • Defined application within the constraints of the operating instructions
  • Technical description of the furnaces: see models LHT 04/16 and LHT 04/17
  • Description of the weighing system: see models L 9/... SW
  • Process control and documentation for temperature and combustion loss via VCD software package for monitoring, documentation and control
Available Model Number : LHT 04/16 SW, LHT 04/17 SW High-Temperature Furnaces with Molybdenum Disilicide Heating Elements with Fiber Insulation up to 1800 °C

High-temperature furnace HT 16/18 with gas supply system

High-temperature furnace HT 160/17 with gas supply system

Reinforced floor as protection for bottom insulation for high-temperature furnace HT 16/16 and higher

Inner process top hat with gas injection through the furnace bottom protects the furnace chamber against contamination and/or prevents chemical interaction between the charge and heating elements

High-temperature furnace HT 64/16S with pneumatically driven and parallel lift door

Two-door design for high-temperature furnaces > HT 276/..

Available Model Number : HT 04/16, HT 08/16, HT 16/16, HT 40/16, HT 64/16, HT 128/16, HT 160/16, HT 276/16,

HT 450/16, HT 04/17, HT 08/17, HT 16/17, HT 40/17, HT 64/17, HT 128/17, HT 160/17, HT 276/17, HT 450/17, HT 04/18,

HT 08/18, HT 16/18, HT 40/18, HT 64/18, HT 128/18, HT 160/18, HT 276/18, HT 450/18,

High-Temperature Furnaces with SiC Rod Heating up to 1550 °C

High-temperature furnace HTC 40/16

Vertically mounted SiC rods and optional perforated air inlet tubes of the debinding system in a high-temperature furnace

Exhaust air flap and charge thermocouple including a stand as additional equipment

The high-temperature furnaces HTC 16/16 - HTC 450/16 are heated by vertically hung SiC rods, which makes them especially suitable for sintering processes up to a maximum operating temperature of 1550 °C. For some processes, e.g. for sintering zirconium oxide, the absence of interactivity between the charge and the SiC rods, these models are more suitable than the alternatives heated with molybdenum disilicide elements. The basic construction of these furnaces make them comparable with the already familiar models in the HT product line and they can be upgraded with the same additional equipment.

  • Tmax 1550 °C
  • Dual shell housing with fan cooling for low shell temperatures
  • Heating from both sides via vertically mounted SiC rods
  • High-quality fiber insulation backed by special insulation
  • Side insulation constructed with tongue and groove blocks provides for low heat loss to the outside
  • Long-life roof insulation with special suspension
  • Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
  • Chain-guided parallel swivel door for defined opening and closing of the door without destroying the insulation
  • Two-door design (front/back) for high-temperature furnaces > HTC 276/..
  • Labyrinth sealing ensures the least possible temperature loss in the door area
  • Reinforced floor as protection for bottom insulation
  • Exhaust air opening in the furnace roof
  • Heating elements switched via SCR's
  • Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and load
  • Defined application within the constraints of the operating instructions
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive

Available Model Number : HTC 16/16, HTC 40/16, HTC 64/16, HTC 128/16, HTC 160/16, HTC 276/16, HTC 450/16

High Temperature Furnaces with Molybdenum Disilicide Heating Elements with Refractory Brick Insulation up to 1700 °C

High-temperature furnace HFL 16/17 DB50 High-temperature furnace HFL 160/17
Protection grid in front of heating elements prevent against mechanical damages Gas supply system for non-flammable protective or reaction gases The high-temperature furnaces HFL 16/16 HFL 160/17 are characterized by their lining with robust light refractory bricks. This version is recommended for processes producing aggressive gases or acids, such as under glass melting.

Standard equipment like high-temperature furnaces HT, except:

  • Tmax 1600 °C or 1700 °C
  • Robust refractory brick insulation and special backing insulation
  • Furnace floor made of lightweight refractory bricks accommodates high charge weights
  • Defined application within the constraints of the operating instructions
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive

Available Model Number : HFL 16/16, HFL 40/16, HFL 64/16, HFL 160/16, HFL 16/17, HFL 40/17, HFL 64/17,

HFL 160/17

      Ovens and Forced Convection Chamber Furnaces  

Oven TR 60 with adjustable fan speed Oven TR 240
Electrical rotating device as additional equipment Extricable metal grids to load the oven in different layers Oven TR 1050 with double door Oven TR 120 LS with safety technology according to EN 1539 for charges containing liquid solvents Oven TR 450 With their maximum working temperature of up to 300 °C and air circulation, the ovens achieve a perfect temperature uniformity which is much better than in ovens of most competitors. They can be used for various applications such as e.g. drying, sterilizing or warm storing. Ample warehousing of standard models provides for short delivery times.
  • Tmax 300 °C
  • Working temperature range: + 5 °C above room temperature up to 300 °C
  • Ovens TR 30 - TR 240 designed as tabletop models
  • Ovens TR 450 and TR 1050 designed as floor standing models
  • Horizontal, air circulation results in temperature uniformity better than +/- 5 °C
  • Stainless steel chamber, alloy 304 (AISI)/(DIN material no. 1.4301), rust-resistant and easy to clean
  • Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
  • Large handle to open and close the door
  • Charging in multiple layers possible using removeable grids (number of removeable grids included, see table to the right)
  • Large, wide-opening swing door, hinged on the right with quick release for models TR 30 - TR 450
  • Double swing door with quick release for TR 1050
  • TR 1050 equipped transport rollers
  • Infinitely adjustable exhaust at the rear wall with operation from the front
  • PID microprocessor control with self-diagnosis system
  • Solid state relays provide for low­noise operation
  • Defined application within the constraints of the operating instructions
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive

Additional equipment

  • Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the oven and load
  • Infinitely adjustable fan speed of the air circulation fan
  • Window for charge observing
  • Further removeable grids with rails
  • Side inlet
  • Stainless steel collecting pan to protect the furnace chamber
  • Door hinges on the left side
  • Reinforced bottom plate
  • Safety technology according to EN 1539 for charges containing liquid solvents (TR .. LS) up to model TR 240 LS, achievable temperature uniformity +/- 8 °C
  • Transport castors for model TR 450
  • Various modifications available for individual needs
  • Upgrading available to meet the quality requirements of AMS 2750 E or FDA
  • Process control and documentation via VCD software package for monitoring, documentation and control
  Available Model Number : TR 30, TR 60, TR 60 LS, TR 120, TR 120 LS, TR 240, TR 240 LS, TR 450, TR 1050 Chamber Ovens Electrically Heated or Gas-Fired  
Chamber oven KTR 1500 with charging cart Chamber oven KTR 22500/S with chamber lightning and drive-in tracks with insulated plugs which provide for an optimal temperature uniformity
KTR 3100/S for curing of composites in vacuum bags incl. pump and necessary connections in the oven chamber Direct gas-firing at a chamber dryer KTR 4500 with platform cart, inner lightning and observation windows Adjustable plate shutters to adapt the air guide to the charge KTR 3100 DT with rotating system for tempering of silicone parts. Four baskets will be charged in the frame and can be taken out separately Drive-in ramp The chamber ovens of the KTR range can be used for complex drying processes and heat treatment of charges to an application temperature of 260 °C. The high-performance air circulation enables optimum temperature uniformity throughout the work space. A wide range of accessories allow the chamber ovens to be modified to meet specific process requirements. The design for the heat treatment of flammable materials in conformance with EN 1539 (NFPA 86) is available for all sizes.
  • Tmax 260 °C
  • Electrically heated (via a heating register with integrated chrome steel heating elements) or gas-fired (direct or indirect gas-fired including injection of the hot air into the intake duct)
  • Temperature uniformity up to +/- 3 °C according to DIN 17052-1 (for design wihout track cutouts)
  • High-quality mineral wool insulation provides for outer temperatures of < 25 °C above room temperature
  • Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
  • High air exchange for fast drying processes
  • Double-wing door for furnaces KTR 3100 and larger
  • Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the oven and load
  • Incl. floor insulation
  • Defined application within the constraints of the operating instructions
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive

Additional equipment

  • Track cutouts for level drive-in of charging cart
  • Base frame to charge the oven via a charging forklift
  • Additional Door in the back for charging from both sides or to use the oven as lock between two rooms
  • Fan system for faster cooling with manual or motor-driven control of the exhaust flaps
  • Programmed opening and closing of exhaust air flaps
  • Air circulation with speed control, recommendable for processes with light or sensitive charge
  • Observation window and furnace chamber lighting
  • Safety technology according to EN 1539 (NFPA 86) (models KTR .. LS) for charges containing solvents
  • Charging cart with or without rack system
  • Design for clean room heat treatment processes
  • Rotating systems for tempering processes
  • Process control and documentation via VCD software package or Nabertherm Control Center (NCC) for monitoring, documentation and control

Accessories

  • Adjustable plate shutters to adapt the air guide to the charge and improve temperature uniformity
  • Guide-in tracks and shelves
  • Shelves with 2/3 extraction with evenly distributed load on the whole shelve surface
  • Platform cart in combination with drive-in tracks
  • Charging cart with rack system in combination with drive-in tracks
  • Sealing shoes for ovens with drive-in tracks to improve temperature uniformity in the work space
  • All KTR-models are also available with Tmax 300 °C.
Available Model Number : KTR 1000 (LS), KTR 1500 (LS), KTR 3100 (LS), KTR 4500 (LS), KTR 6125 (LS), KTR 6250 (LS), KTR 8000 (LS), KTR 9000 (LS), KTR 12300 (LS), KTR 16000 (LS), KTR 21300 (LS), KTR 22500 (LS)   High-Temperature Ovens, Forced Convection Chamber Furnaces  

Forced convection chamber furnace NA 250/45

Forced convection chamber furnace NA 120/46 with lift door

Forced convection chamber furnace NA 15/65 as table-top model

These chamber furnaces with air circulation are characterized by their extremely high temperature uniformity. Hence, they are especially suitable for processes such as cooling, crystalizing, preheating, curing, but also for numerous processes in tool making. Due to the modular concept, the forced convection furnaces can be adjusted to the process requirements by adding suitable equipment.

  • Tmax 450 °C, 650 °C, or 850 °C
  • Horizontal air circulation
  • Swing door hinged on the right
  • Temperature uniformity up to +/- 4 °C according to DIN 17052-1 (model NA 15/65 up to +/- 5 °C)
  • Optimum air flow and temperature uniformity through high circulation rates
  • One frame sheet and rails for two additional trays included in the scope of delivery (NA 15/65 without frame sheet)
  • Stainless steel air-baffles in the furnace for optimum air circulation
  • Base frame included in the delivery, NA 15/65 designed as table-top model
  • Air inlet and exhaust air flaps as additional equipment for using as drying oven
  • Defined application within the constraints of the operating instructions
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive

Available Model Number : NA 30/45, NA 60/45, NA 120/45, NA 250/45, NA 500/45, NA 15/65, NA 30/65, NA 60/65, NA 120/65, , NA 250/65, NA 500/65, N 30/85 HA, N 60/85 HA, N 120/85 HA, N 250/85 HA, N 500/85 HA

Sealed Forced Convection Chamber Furnaces NA-I and NA-SI

Forced convection chamber furnace NA 120/65 I Forced convection chamber furnace NA 15/65 I as tabletop model with manual gas supply system
Sealed forced convection chamber furnaces are suitable if a heat treatment process up to 650 °C requires a protective gas atmosphere that does not have to be completely oxygen free. The difference between the two variants is that the I-model only has a sealed outer housing while the SI-model has a welded inner box, which further reduces the residual oxygen concentration.

NA-I design Like forced convection chamber furnaces < 675 l (page 34) with the following changes

  • Tmax 450 °C and 650 °C
  • Silicone door seal
  • Furnace housing sealed with silicone
  • Protective gas connection in the back wall
  • Defined application within the constraints of the operating instructions
  • Residual oxygen concentration < 1 % depending on the volume and type of protective gas
  • For non-flammable protective and reaction gases such as argon, nitrogen, and forming gas (national regulations must be considered)

NA-SI design Additional features

  • Tmax 650 °C
  • Welded inner housing
  • 2-sided heating and air circulation
  • Door sealed with seal gas
  • Sealed connection to circulation motor
  • Gas inlet via circulator shaft
  • Defined application within the constraints of the operating instructions
  • Residual oxygen concentration to 0.1 % depending on the volume and type of protective gas
  • For non-flammable protective and reaction gases such as argon, nitrogen, and forming gas (national regulations must be considered)

Available Model Number : NA 30/45 I, NA 60/45 I, NA 120/45 I, NA 250/45 I, NA 500/45 I, NA 675/45 I, NA 15/65 I1, NA 30/65 I, N A 60/65 I (SI), NA 120/65 I (SI), NA 250/65 I (SI), NA 500/65 I (SI), NA 675/65 I

Chamber Furnaces for Processes with High Vaporization Rates of Organic Matter or for Thermal Cleaning by Ashing Electrically Heated or Gas-Fired

Chamber furnace N 650/14 BO with ignition burner The chamber furnaces of the model series N(B) .. BO are used for processes with large amounts of organic matters or high vaporization rates. These models can be used for products which are insensitive against temporarily uncontrolled temperature increases. Processes in which the product or contaminations on the product are ashed by ignition can be also carried out safely in this type of chamber furnace. Examples include residual wax removal of pouring clustersfollowed by sintering, or thermal cleaning of oxide catalytic honey combs from soot or fuel residues. The electrically heated N...BO furnaces can be used for processes with exact temperature control and uniformity. For safety reasons, they are equipped with an integrated gas torch for igniting the flammable components in the gas mixture. The accumulation of flammable components is avoided and their safe combustion is ensured. The gas-fired NB…BO furnaces are designed for processes which require a heat-up time to temperatures > 500 °C The burning of unwanted organic ingrediants can take place at temperatures > 500 °C. Following this, a subsequent process can take place up to max. 1400 °C (electrically) or up to 1000 °C (gas-fired). For safety, the furnace door locks after the program was started and cannot be opened again until the temperature has dropped below a defined value. In case of burner malfunction or gas shortage the process is aborted.

Chamber furnaces N 100 BO - N 650/14 BO, electrically heated and gas-fired ignition flame

  • Tmax 1000 °C or 1400 °C
  • Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
  • Standard sizes up to 650 liters furnace chamber, additional sizes on request
  • Exhaust hood
  • Fully automatic temperature control
  • Optional thermal afterburning
  • Ignition flame using natural gas or liquid gas (LPG)
  • Defined application within the constraints of the operating instructions

Chamber furnaces models NB 300 BO and NB 650 BO, gas-fired

  • Tmax 1000 °C
  • Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
  • Standard sizes up to 650 liters furnace chamber, additional sizes on request
  • Integrated thermal afterburning
  • Gas burners operating with natural gas or liquid gas (LPG)
  • Defined application within the constraints of the operating instructions

Available Model Number : N 100 BO, N 300 BO, N 300/14 BO, N 650/14 BO, NB 300 BO, NB 650 BO       Clean Room Solutions  

KTR 8000 designed as a production oven in the clean room with filters for air circulation

Hot-wall retort furnace NRA 1700/06 with charging frame for installation in grey room with charging door in clean room

High-temperature furnace with loading from the clean room; switchgear and furnace installed in grey room

Forced convection chamber oven NAC 250/45 with clean room specs

Clean room applications impose particularly high requirements to the design of the chosen furnace. If the complete furnace is operated in a clean room an essential contamination of the clean room atmosphere must be avoided. Especially, the particle contamination must be reduced to a minimum.

The specific application determines the choice of the required furnace technology. In many cases forced convection furnaces are required to achieve the necessary temperature uniformity at lower temperatures. For higher temperatures, Nabertherm has also delivered many furnaces with radiant heating.

Furnace Installation in the Clean Room

If the complete furnace is supposed to be positioned in the clean room, then it is important that both the furnace chamber and the furnace housing as well as the controls provide for good protection against contamination. Surfaces must be easy to clean. The furnace chamber is tightly sealed to the insulation behind it. If necessary, additional equipment such as filters for the fresh air supply or the air circulation in the furnace can be used to improve the cleanliness class. It is recommended to install the switchgear and the furnace controls outside the clean room.

Furnace Installation in the Grey Room, Furnace Charging from the Clean Room

Optimal results with respect to cleanness will be achieved by placing the furnace in the grey room with charging from the clean room. This significantly reduces the amount of costly space needed in the clean room to a minimum. The front and the furnace interior in the clean room are designed for easy cleaning. With this configuration even the highest clean room classes can be achieved.

Sluice Furnace between Grey Room and Clean Room

Logistics between clean room and grey room can often be easily sorted out. Lock furnaces with one door in the grey room and the other door in the clean room are the perfect choice for these applications. The inner chamber as well as the furnace front in the clean room will be especially designed for lowest particle contamination.

Please contact us if you are looking for a heat treatment solution under clean room conditions. We would be pleased to quote for the oven or furnace model that meets best your requirements.

    Tube Furnaces and Accessories  
RD 30/200/11
Over-temperature limiter The RD tube furnaces convince with their unbeatable price-performance ratio, very compact outer dimensions and their low weight. These all-rounders are equipped with a working tube which also serves as support for the heating wires. Thus, the working tube is part of the furnace heating which has the advantage that the furnaces achieve very high heat-up rates. The tube furnaces can be supplied for 1100 °C or 1300 °C. Both models are designed for horizontal application. If the customer requires protective gas atmosphere, a separate working tube incl. gas supply system 1, e.g. made of quartz glass, must be inserted in the working tube.
  • Tmax 1100 °C or 1300 °C
  • Dual shell housing made of sheets of textured stainless steel
  • Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
  • Inner diameter of the tube: 30 mm, heated length: 200 mm
  • Working tube made of C 530 material including two fiber plugs as standard
  • Thermocouple type K (1100 °C) or type S (1300 °C)
  • Solid state relays provide for low-noise operation of the heating
  • Heating wires wound directly around the working tube resulting in very fast heat-up rates
  • Defined application within the constraints of the operating instructions

Additional equipment

  • Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and load
  • Gas supply system for non-flammable protective or reactive gas
Available Model Number : RD 30/200/11, RD 30/200/13  
Tube furnace R 170/1000/13 Tube furnace R 50/250/13 with gas supply system 2
These compact tube furnaces with integrated control systems can be used universally for many processes. Equipped with a standard working tube of C 530 ceramic and two fiber plugs, these tube furnaces have an unbeatable price/performance ratio.
  • Tmax 1200 °C or 1300 °C
  • Single-zoned design as standard
  • Dual shell housing made of sheets of textured stainless steel
  • Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
  • Outer tube diameter of 50 mm to 170 mm, heated length from 250 mm to 1000 mm
  • Working tube of C 530 ceramic including two fiber plugs as standard equipment
  • Tmax 1200 °C: Type N thermocouple
  • Tmax 1300 °C: Type S thermocouple
  • Solid state relays provide for low­noise operation
  • Defined application within the constraints of the operating instructions
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive

Additional equipment

  • Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and load
  • Charge control with temperature measurement in the working tube and in the furnace chamber outside the tube
  • Three-zoned design (heated length from 500 mm)
  • Gas supply systems for protective gas or vacuum operation
  • Process control and documentation via VCD software package for monitoring, documentation and control
Available Model Number : R 50/250/12, R 50/500/12, R 120/500/12, R 170/750/12, R 170/1000/12, R 50/250/13, R 50/500/13, R 120/500/13, R 170/750/13, R 170/1000/13 Tube Furnaces with Stand for Horizontal or Vertical Operation  

Tube furnace RT 50-250/11

Tube furnace RT 50-250/13

These compact tube furnaces are used when laboratory experiments must be performed horizontally, vertically, or at specific angles. The ability to configure the angle of tilt and the working height, and their compact design, also make these tube furnaces suitable for integration into existing process systems.

  • Tmax 1100 °C, 1300 °C, or 1500 °C
  • Compact design
  • Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
  • Vertical or horizontal operation freely adjustable
  • Working height freely adjustable
  • Working tube made of C 530 ceramic
  • Type S thermocouple
  • Operation also possible separate from stand if safety guidelines are observed
  • Control system integrated in furnace base
  • Defined application within the constraints of the operating instructions
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
Available Model Number : RT 50-250/11 , RT 50-250/13, RT 30-200/15   High-Temperature Tube Furnaces with SiC Rod Heating Gas Atmosphere or Vacuum  
Tube furnace RHTC 80-230/15 with manual gas supply system Tube furnace RHTC 80-450/15
SiC rod heating These compact tube furnaces with SiC rod heating and integrated switchgear and controller can be used universally for many processes. With an easy to replace working tube as well as additional standard equipment options, these furnaces are flexible and can be used for a wide range of applications. The high-quality fiber insulation ensures fast heating and cooling times. The SiC heating rods installed parallel to the working tube ensure excellent temperature uniformity. The price-performance ratio for this temperature range is unbeatable.
  • Tmax 1500 °C
  • Dual shell housing made of sheets of textured stainless steel
  • Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
  • Active cooling of housing for low surface temperatures
  • Type S thermocouple
  • Solid state relays provide for low-noise operation
  • Prepared for assembly of working tubes with water-cooled flanges
  • Ceramic tube, C 799 quality
  • Defined application within the constraints of the operating instructions
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive

Additional equipment

  • Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and load
  • Charge control with temperature measurement in the working tube and in the furnace chamber outside the tube
  • Fiber plugs
  • Check valve at gas outlet avoids intrusion of false air
  • Working tubes for operation with water-cooled flanges
  • Display of inner tube temperature with additional thermocouple
  • Alternative gas supply systems for protective gas or vacuum operation
  • Process control and documentation via VCD software package for monitoring, documentation and control
  Available Model Number : RHTC 80-230/15, RHTC 80-450/15, RHTC 80-710/15   High-Temperature Tube Furnaces for Horizontal and Vertical Operation up to 1800 °C Gas Atmosphere or Vacuum    
Tube furnace RHTH 120/600/17 Tube furnace RHTV 120/480/16 LBS with working tube closed at one side, protective gas and vacuum option as well as with electric screw drive of the lift table
RHTV 50/150/17 vertical tube furnace with stand and gas supply system 2 as additional equipment Tube furnace RHTH 120/600/18 The high-temperature tube furnaces are available in either horizontal (type RHTH) or vertical (type RHTV) designs. High-quality insulation materials made of vacuum-formed fiber plates enable energy-saving operation and a fast heating time due to low heat storage and heat conductivity. By using different gas supply systems, operations can be performed under non-flammable or flammable protective or reactive gases or under vacuum.
  • Tmax 1600 °C, 1700 °C, or 1800 °C
  • MoSi2 heating elements, mounted vertically for easy replacement
  • Insulation with vacuum-formed ceramic fiber plates
  • Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
  • Rectangular outer housing with slots for convection cooling
  • Tube furnaces RHTV with frame for vertical operation
  • Dual shell housing made of sheets of textured stainless steel
  • Ceramic working tube made of material C 799 incl. fiber plugs for operation under air
  • Type B thermocouple
  • Power unit with low-voltage transformer and thyristor
  • Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and load and with selectable maximum temperature gradient as tube protection
  • Switchgear and control unit separate from furnace in separate floor standing cabinet
  • Defined application within the constraints of the operating instructions
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive

Additional equipment

  • Charge control with temperature measurement in the working tube and in the furnace chamber outside the tube
  • Display of inner tube temperature with additional thermocouple
  • Gas tight flanges for protective gas and vacuum operation
  • Manual or automatic gas supply system
  • Three-zone control for optimization of temperature uniformity (only tube furnaces RHTH)
  • Check valve at gas outlet avoids intrusion of false air
  • Process control and documentation via VCD software package or Nabertherm Control Center (NCC) for monitoring, documentation and control
Available Model Number ;   Horizontal design : RHTH 50/150/.., RHTH 80/300/.., RHTH 120/600/. Vertical design : RHTV 50/150/.., RHTV 80/300/.., RHTV 120/600/..   Horizontal or Vertical Operation up to 1300 °C Gas Atmosphere or Vacuum
Tube furnace RSV 170/1000/11 with gas supply system 2 Tube furnace RSH 80/500/13 with gas tight tube and water-cooled flanges
Tube furnace RS 120/750/13 with gas supply system 4, hydrogen applications Quartz glass and flanges for protective gas operation as optional equipment Tube furnace RSH 120/1000/11S, three-zone controlled, incl. zone separators to reach a temperature gradient Tube furnace RSH 50/500/13 These tube furnaces can be used for horizontal (RSH) or vertical (RSV) operation. The split-type design makes it easy to change the working tube. It allows for a comfortable exchange of various working tubes (e.g. working tubes made of different materials). Using the wide range of accessories these professional tube furnaces can be optimally tailored to your process. By upgrading the furnaces with different gas supply systems the operation in a protective gas atmosphere, under vacuum or under flammable protective or reactive gases is possible. Besides convenient standard controllers for process control modern PLC control systems are also available.
  • Tmax 1100 °C or 1300 °C
  • Dual shell housing made of sheets of textured stainless steel
  • Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
  • Tmax 1100 °C: Type N thermocouple
  • Tmax 1300 °C: Type S thermocouple
  • Frame for vertical operation (RSV)
  • Split-type design for simple insertion of the working tube
  • Working tube made of material C 530 incl. fiber plugs for operation under air in scope of delivery
  • Heating elements on support tubes provide for free radiation
  • RSV: switchgear and control unit separate from furnace in own wall or standing cabinet
  • RSH: switchgear and control unit integrated in furnace housing
  • Defined application within the constraints of the operating instructions
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive

Additional equipment

  • Charge control with temperature measurement in the working tube and in the furnace chamber outside the tube
  • Display of inner tube temperature with additional thermocouple
  • Different gas supply systems for non-flammable or flammable protective or reactive gases and vacuum operation
  • Three-zone control for optimization of temperature uniformity
  • Cooling systems for accelerated cooling of the working tube and charge
  • Check valve at gas outlet avoids intrusion of false air
  • Base frame with integrated switchgear and controller
  • Process control and documentation via VCD software package or Nabertherm Control Center (NCC) for monitoring, documentation and control

Available Model Number ; RSH 50/250/.., RSH 50/500/.., RSH 80/500/.., RSH 80/750/.., RSH 120/500/.,

RSH 120/750/., RSH 120/1000/, RSH 170/750/, RSH 170/1000/, RSV 50/250/.., RSV 50/500/., RSV 80/500/.., RSV 80/750/., RSV 120/500/, RSV 120/750/., RSV 120/1000/., RSV 170/750/.., RSV 170/1000/.

Rotary Tube Furnaces for Batch Operation up to 1100 °C

Rotary tube furnace RSRB 80/500/11 as tabletop version for batch operation Rotary tube furnace RSRB 120/500/11
Rotary tube furnace tilted towards the right side for charging and batch operation Rotary tube furnace tilted towards the left side to discharge Connection set for vacuum operation Gas tight closing plug for tubes made of quartz glass closed at one side The rotary tube furnaces of the RSRB series are ideally suited for batch operation. The permanent rotation of the working tube ensures that the charge is constantly in motion. Due to the special shape of the quartz reactor with the tapered pipe ends the batch is kept in the rotary tube furnace and can be heat-treated an arbitrarily long time period time; a controlled heating to the temperature profiles is also possible.
  • Tmax 1100 °C
  • Thermocouple type K
  • Dual shell housing made of sheets of textured stainless steel
  • Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
  • Tube furnace designed as table-top model with quartz glass reactor which opens on both sides, tapered ends
  • Reactor is removed for emptying out of the rotary tube furnace. Beltless drive and hinged furnace housing (opening temperature < 180 °C) provide for very easy removal through
  • Adjustable drive of approx. 2-45 rpm
  • Switchgear and control unit separate from tube furnace in own wall or standing cabinet
  • Defined application within the constraints of the operating instructions
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive

Additional equipment

  • Three-zone control for the optimization of temperature uniformity
  • Temperature display unit in the working tube with measurement by means of an additional thermocouple
  • Charge control by means of an additional thermocouple in the working tube
  • Different gassing ensures good flushing of the charge with process gas through inlet on one side and outlet on other side of tube
  • Gas-tight rotary feedthrough for connection of the rotating reactor to a gas supply system
  • Check valve at gas outlet avoids intrusion of false air
  • Vacuum design, up to 10-2 mbar depending on the applied pump
  • Open on both sides reactor made of quartz glass with knobs for better mixing of the charge in the tube
  • Package for improved charging and discharging of the working tube in the following design:
  • Mixing reactor made of quartz glass with integrated blade for better mixing of the batch, closed on one side, large opening on the other side
  • Tilting mechanism to the left/to the right. For charging and heat treatment, the furnace is tilted towards the right side until the stop so that the load is charged into the rotary tube furnace. For discharge, the furnace is tilted towards the other side to discharge the powder from the reactor. It is no longer necessary to remove the reactor.
  • Rotary tube furnace assembled on base with integrated switchgear and controller, incl. transport casters
  • Process control and documentation via VCD software package or Nabertherm Control Center (NCC) for monitoring, documentation and control
  Available Model Number: RSRB 80-500/11, RSRB 80-750/11, RSRB 120-500/11, RSRB 120-750/11, RSRB 120-1000/11   Rotary Tube Furnaces for Continuous Processes up to 1300 °C
Rotary tube furnace RSRC 80/500/11 for processes under protective gas or in vacuum Rotary tube furnace RSRC 120/750/13
Screw-conveyor with adjustable speed Screw-conveyors with different pitches for the adaption to the charge Vibrating channel on the rotary tube for convenient material feeding Vibration generator at the charging funnel for improved powder supply The RSRC rotary tube furnaces are particularly suitable for processes where continuously running batch material is heated for a short time. The rotary tube furnace is positioned slightly inclined heated-up to the target temperature. The material is then continuously supplied at the upper end of the tube. It passes through the heated area of the tube and falls on the lower end out of the tube. The time of heat treatment results from the inclination angle, the rotational speed and the length of the working tube, as well as from the flow properties of the batch material. Equipped with the optional closed loading system for 5 liter charge material incl. receptacle, the rotary tube furnace can also be used for processes under protective gas or vacuum.

Depending on process, charge and required maximum temperature, different working tubes made of quartz glass, ceramics or metal are used (see page 50). This rotary tube furnace is therefore highly adaptable for different processes.

  • Tmax 1100 °C
    • Working tube made of quartz glass open at both sides
    • Thermocouple type K
  • Tmax 1300 °C
    • Open tube made of ceramics C 530
    • Thermocouple type S
  • Heating elements on support tubes provide for free radiation
  • Dual shell housing made of sheets of textured stainless steel
  • Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
  • Adjustable drive of approx. 2-45 rpm
  • Digital display unit for the tilting angle of the rotary tube furnace
  • Beltless drive and split-type furnace housing (opening temperature < 180 °C) provide for very easy tube removal
  • Compact system, rotary tube furnace positioned on a base frame with
  • Manual spindle drive with crank to preset the tilting angle
  • Switchgear and controls integrated
  • Castors
  • Defined application within the constraints of the operating instructions
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive

Additional equipment

  • Three-zone control for the optimization of temperature uniformity
  • Temperature display unit in the working tube with measurement by means of an additional thermocouple
  • Charge control by means of an additional thermocouple in the working tube
  • Different gassing systems with good flushing of the charge with process gas (also possible with hydrogen) in counterflow (only in combination with feeding system below)
  • Vacuum design, up to 10-2 mbar depending on the applied pump
  • Vibrating channel and extension piece on the rotary tube for convenient material supply/removal, suitable for processes in normal atmosphere
  • Charging system for continuous material transport, consisting of:
  • Stainless steel funnel incl. electric vibration generator to optimize the material feeding into the working tube
  • Electrically driven screw-conveyor at the inlet of the working tube with 10, 20 or 40 mm pitch and adjustable speed between 0.28 and 6 revolutions per minute, different gear transmissions for other speeds on request
  • Collecting bottle made of laboratory glass at the outlet of the working tube
  • Suitable for operation in gas atmosphere or vacuum
  • Working tubes made of differents materials
  • Quartz glass batch reactors, Tmax 1100 °C
  • Higher temperatures up to 1500 °C available on request
  • PLC controls for temperature control and the control of connected aggregates such as gearshift and speed of the screw-conveyor, speed of the working tube, switching of the vibration generator, etc.
  • Process control and documentation via VCD software package or Nabertherm Control Center (NCC) for monitoring, documentation and control
Available Model Number: RSRC 80-500/11, RSRC 80-750/11, RSRC 120-500/11, RSRC 120-750/11, RSRC 120-1000/11, RSRC 80-500/13, RSRC 80-750/13, RSRC 120-500/13, RSRC 120-750/13, RSRC 120-1000/13   Gas Supply Systems/Vacuum Operation for Tube Furnaces

Gas supply system 1: Fiber plugs with protective gas connection, suitable for many laboratory applications Water-cooled stainless steel flange Gas supply system for non-flammable protective or reactive gas with shutoff valve and flow meter with regulator valve, optionally with magnetic valve Observation window as additional equipment for gas tight flanges When equipped with various equipment packages, the tube furnace product lines can be adapted for operation with nonflammable or flammable gasses or for vacuum operation.

Gas Supply System 1 for non-flammable protective or reactive gases Not gastight, no vacuum operation

This package represents a basic version sufficient for many applications, for operation with non-flammable protective or reactive gasses. The standard working tube made of ceramic C 530 delivered with the furnace can still be used.
  • Available for tube furnaces RD, R, RT, RSH and RSV
  • Standard working tube can be used
  • 2 plugs made of porous, non-classified ceramic fiber incl. protective gas connections
  • Gas supply system for nonflammable protective gas (Ar, N2, forming gas, others on request) with shutoff valve and flow meter with control valve, optionally with magnetic valve. One gas intake pressure at 300 mbar to be provided by customer.

Additional equipment

  • Extension of gas supply system with a second or third nonflammable type of gas
  • Bottle pressure regulator for use with bottled gas
  • Automatic switching on/off by means of the program segments of the controller, only possible with control systems which include programmable extra functions

Gas Supply System 2 for non-flammable protective or reactive gases/vacuum operation

For increased atmospheric purity requirements in the working tube, we recommend this gas supply system. The system can also be equipped for vacuum operation.
  • Available for tube furnaces R, RSH, RSV, RSRB, RSRC, RHTC, RHTH, RHTV
  • Gas supply system for nonflammable protective gas (Ar, N2, forming gas, others on request) with shutoff valve and flow meter with control valve, optionally with magnetic valve. One gas intake pressure at 300 mbar to be provided by customer.
  • Additional equipment for static tube furnaces:
    • Longer, gas tight working tube of ceramic C 610 for furnaces to 1300 °C or of C 799 for temperatures above 1300 °C
    • 2 vacuum-tight, water-cooled stainless steel flanges with fittings on the outlet side (cooling water supply with NW9 hose connector to be provided by the customer)
    • Mounting system on furnace for the flanges
  • Additional equipment for RSRC models (continuous operation): charging system
  • Additional Equipment for RSRB models: gas-tight rotarylead-outs on gas inlet and outlet, gas cooler and gas outlet valve

Additional equipment

  • Extension of gas supply system with a second or third nonflammable type of gas
  • Bottle pressure regulator for use with bottled gas
  • Automatic switching on/off by means of the program segments of the controller, only possible with control systems which include programmable extra functions
  • Gas-supply programmable via mass-flow controllers (only in combination with PLC-controls)
  • Process tubes made of different materials
  • Quick-locks for watercooled flanges
  • Cooling unit for closed loop water circuit
  • Window for charge observation in combination with gas tight flanges

Vacuum Operation

  • Vacuum package for evacuation of the working tube, consisting of connector for the gas outlet, ball valve, manometer, manually operated rotary vane vacuum pump with corrugated stainless steel hose connected to the gas outlet, max. attainable end pressure in working tube depending on pump type
  • Pumps for max. final pressure of up to 10-5 mbar (models RSRB/RSRC up to 10‑2 mbar) on request
  • The decrease in strength of the working tube at high temperatures limits the maximum operating temperature under vacuum
RHTH 120-600/18 with gas supply system4 for hydrogen operation Water-cooled end flange with quick connectors as additional equipment

Gas Supply System 4 for hydrogen, fully-automatic, unattended operation

Adding gas supply system 4 to the tube furnace allows operation under a hydrogen atmosphere. During hydrogen operation, a safety pressure of approx. 30 mbar is ensured in the working tube. Surplus hydrogen is burnt off in an exhaust gas torch. With extended safety logic and an integrated nitrogen purge container, the system can be used for fully-automatic, unattended operation. Equipped with a Safety-PLC control system, pre-purging, hydrogen inlet, operation, fault monitoring and purging at the end of the process are carried out automatically. In case of default, the tube is immediately purged with nitrogen and the system is automatically switched to a safe status.
  • Available for tube furnaces RSH, RSV, RSRC, RHTH and RHTV
  • Safety system for operation with flammable gases including monitoring of torch function and overpressure
  • Extended safety control system with emergency tube purging in case of default
  • Emergency purge container
  • Safety-PLC control system with touchpanel for data input
  • Exhaust gas torch
  • Pressure switch for monitoring the safety pressure
  • Gas supply system for H2 and N2. Volume adjustment is carried out by hand (the customer provides an H2 supply at 1 bar, an N2 supply at 10 bar, an O2 supply at 6-8 bar and a propan supply at 300 mbar)

Additional equipment

  • Gas supply system extension for additional nonflammable gas types
  • Operation with other flammable gases on request
  • Bottle pressure reducer for use with bottled gas
  • Cooling unit for closed loop water circuit
  • Vacuum packages (with hydrogen operation, this package can only be used for pre-evacuation)
  • Gas supply via program-dependent, controllable mass flow controllers
Vacuum Pumps Vacuum pump stand for operation up to 10-5 mbar Independent pressure gauge for a pressure range of 10-3 mbar or 10-9 mbar

With respect to the final pressure different pumps are available

  • Single-step rotary piston pump for a max. final pressure of approx. 20 mbar.
  • Two-step rotary piston pump for a max. final pressure of approx. 10-2 mbar.
  • Turbomolecular pump stand (rotary vane pump with following turbomolecular pump for a max. final pressure of 10-5 mbar.
  • Independent pressure gauge for a pressure range of 10-3 mbar or 10-9 mbar as additional equipment

Information:

For protection of the vacuum pump only cold stage evacuation is allowed.     Control Alternatives for Tube Furnaces   Three-Zone Furnace Chamber Control Furnace control Charge control Thermocouple for charge control in the RHTH 120/600/18 furnace Sintering under hydrogen in a tube furnace of RHTH product line

Three-Zone Furnace Chamber Control

The temperature is measured by thermocouples positioned outside of the working tube, one in the middle and two on the sides. The outer zones are controlled with a setpoint-offset in relation to the middle zone. This allows the heat loss at the ends of the tube to be compensated to ensure an extended zone of constant temperature (+/- 5 K).

Furnace Chamber Control with temperature measurement in furnace chamber outside the working tube.

  • Advantages: Thermocouple protected against damage and aggressive load, very even control, attractive price
  • Disadvantage: Temperature difference between displayed temperature on the controller and inside the tube

Extension Package for Furnace Chamber Control

  • with additional temperature measurement in the working tube and display of the measured temperature
  • Advantages: Very precise and rapid control adjustment
  • Disadvantage: Costs

Furnace Chamber vs. Charge Control Comparison

Furnace Chamber Control

Only the furnace chamber temperature is measured and controlled. Regulation is carried out slowly to avoid out-of-range values. As the charge temperature is not measured and controlled, it may vary a few degrees from the chamber temperature.

Charge Control

If the charge control is switched on, both the charge temperature and furnace chamber temperature are measured. By setting different parameters the heat-up and cooling processes can be individually adapted. This results in a more precise temperature control at the charge.   Customized Tube Furnaces   Working Tubes for Tube Furnaces   Melting Furnaces up to 1500 °C  
Melting furnace K 4/10 Melting furnace KC 2/15
Melting furnace KC 2/15 These compact melting furnaces for the melting of non-ferrous metals and alloys are one of a kind and have a number of technical advantages. Designed as tabletop models, they can be used for many laboratory applications. The practical counter balanced hinge with shock absorbers and the spout (not for KC) on the front of the furnace make exact dosing easy when pouring the melt. The melting furnaces are available for furnace chamber temperatures of 1000, 1300, or 1500 °C. This corresponds to melt temperatures of about 80 °C - 110 °C lower.
  • Tmax 1000 °C, 1300 °C, or 1500 °C, with melt temperature about 80 °C - 110 °C lower
  • Crucible sizes of 0,75, 1,5 or 3 liters
  • Crucible with integrated pouring spout of iso-graphite included with delivery
  • Additional spout (not for KC), mounted at the furnace for exact pouring
  • Compact bench-top design, simple emptying of crucible by tiltiing system with gas damper
  • Crucible for heating up of melting furnace insulated with a hinged lid, lid opened when pouring
  • Defined application within the constraints of the operating instructions

Additional equipment

  • Other crucible types available, e.g. steel
  • Design as bale-out furnace without tilting device, e.g. for lead melting
  • Over-temperature limiter for the furnace chamber with automatic reset to protect against overtemperature. The limit controller switches off the heating when the pre-set limit temperature has been reached and does not switch it on again until the temperature falls below the setting again.
  • Observation hole for melt

Available Model Number: K 1/10, K 2/10, K 4/10, K 1/132, K 2/132, K 4/132, KC 1/153, KC 2/153

  Fast-Firing Furnaces up to 1300 °C  

Fast-firing furnace LS 25/13

Firing curves of fast-firing furnaces LS 12/13 and LS 25/13

These fast-firing furnaces are ideal for simulation of typical fast-firing processes up to a maximum firing temperature of 1300 °C. The combination of high performance, low thermal mass and powerful cooling fans provides for cycle times from cold to cold up to 35 minutes with an opening temperature of approx. 300 °C.

  • Tmax 1300 °C
  • Very compact design
  • Ceramic grid tubes as charge support
  • Floor and lid heating
  • Two-zone control, bottom and lid
  • Integrated cooling fans, programmable to speed up charge cooling including housing cooling
  • Programmable lid opening of approximately 60 mm for faster cooling without activating the fan
  • Thermocouple type S for top and bottom zone
  • Castors for easy furnace moving
  • Defined application within the constraints of the operating instructions
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
  Available Model Number: LS 12/13, LS 25/13   Gradient or Lab Strand Annealing Furnaces up to 1300 °C  
Gradient furnace GR 1300/13S Furnace chamber of gradient furnace GR 1300/13 with second door as additional equipment
The furnace chamber of the gradient furnace GR 1300/13 is divided in six control zones of equal length. The temperature in each of the six heating zones is separately controlled. The gradient furnace is usually charged from the side through the parallel swivel door. A maximum temperature gradient of 400 °C can then be stabilized over the heated length of 1300 mm. On request the furnace also is designed as a lab strand annealing furnace with a second door on the opposite side. If the included fiber separator are used charging is carried-out from the top.
  • Tmax 1300 °C
  • Heated length: 1300 mm
  • Heating elements on support tubes providing for free heat radiation in the kiln chamber
  • Charging from the top or through the right side door
  • Gas damper suspension of the lid
  • 6-zone control
  • Separate control of heating zones (each 160 mm long)
  • Temperature gradient of 400 °C over the entire length of the kiln chamber, each zone can individually be controlled
  • Fiber separators dividing the chamber in six equally sized chambers
  • Defined application within the constraints of the operating instructions

Additional equipment

  • Up to ten control zones
  • Second parallel swivel door for use as lab strand annealing furnace
  • Vertical instead of horizontal strand furnace
  • Process control and documentation via Nabertherm Control Center (NCC) for monitoring, documentation and control
Available Model Number: GR 1300/13     Retort Furnaces

Schematic presentation of a hot-wall retort furnace with additional equipment 1 Retort 2 Heating 3 Insulation 4 Gas management system 5 Vacuum pump 6 Fan for indirect cooling 7 Outlet indirect cooling 8 Exhaust torch 9 Fan for gas circulation (NRA models) 10 Charging frame 11 Emergency flushing container

Inside heating in retort furnaces NRA ../06 These gas tight retort furnaces are equipped with direct or indirect heating depending on temperature. They are perfectly suited for various heat treatment processes requiring a defined protective or a reaction gas atmosphere. These compact models can also be laid out for heat treatment under vacuum up to 600 °C. The furnace chamber consists of a gas tight retort with water cooling around the door to protect the special sealing. With the corresponding safety technology, retort furnaces are also suitable for applications under reaction gases, such as hydrogen or, in combination with the IDB package, for inert debinding or for pyrolysis processes. Different model versions are available depending on the temperature range:

Models NRA ../06 with Tmax 650 °C

  • Heating elements located inside the retort
  • Temperature uniformity up to +/- 5 °C inside the work space
  • Retort made of 1.4571
  • Gas circulation fan in the back of the retort provides for optimal temperature uniformity
  • Insulation made of mineral wool

Models NRA ../09 with Tmax 950 °C

  • Design like models NRA ../06 with following differences:
  • Outside heating with heating elements around the retort
  • Retort made of 1.4828
  • Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2

Models NR ../11 with Tmax 1100 °C

  • Design like models NRA ../09 with following differences:
    • Retort made of 1.4841
    • Without gas-circulation
Retort furnace NRA 25/09 Retort furnace NRA 150/09 with controls H1700 and bayonet door lock
Vacuum pump for cold evacuation of the retort

Basic version

  • Compact housing in frame design with removable stainless steel sheets
  • Controls and gas supply integrated in the furnace housing
  • Welded charging supports in the retort resp. air-baffle box in the furnaces with atmosphere circulation
  • Swivel door hinged on right side
  • Open cooling water system
  • Depending on furnace volume for 950 °C- and 1100 °C-models the control system is divided in one or more heating zones
  • Furnace temperature control with measurement outside the retort
  • Gas supply system for one non-flammable protective or reaction gas with flow meter and magnetic valve
  • Port for vacuum pump for cold evacuation
  • Operation under vacuum up to 600 °C with optional single-stage rotary vane pump
  • Defined application within the constraints of the operating instructions
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive

Additional equipment

  • Upgrade for other non-flammable gases, H2 version for flammable gases
  • Automatic gas injection, including MFC flow controller for alternating volume flow, controlled with process control H3700, H1700
  • Vacuum pump for evacuating of the retort up to 600 °C, attainable vacuum up to 10-5 mbar subject to selected pump
  • Indirect cooling
  • Direct cooling
  • Heat exchanger with closed-loop cooling water circuit for door cooling
  • Measuring device for residual oxygen content
  • Door heating
  • Temperature control as charge control with temperature measurement inside and outside the retort
  • Retort, made of 2.4633 for Tmax 1150 °C
  • Process control and documentation via VCD software package or Nabertherm Control Center (NCC) for monitoring, documentation and control

Retort furnace NRA 400/03 IDB with thermal post combustion system

IDB Version for Debinding under Non-flammable Protective Gases or for Pyrolysis Processes

The retort furnaces of the NR and NRA product line are perfectly suited for debinding under non-flammable protective gases or for pyrolysis processes. The IDB version of the retort furnaces implements a safety concept by controlled inerting the furnace chamber with a protective gas. Exhaust gases are burned in a termal post combustion. Both the purging and the torch function are monitored to ensure a safe operation.

  • Process control under monitored overpressure
  • Process control H1700 with PLC controls and graphic touch panel for data input
  • Monitored gas pre-pressure of the process gas
  • Bypass for safe flushing of furnace chamber with inert gas
  • Thermal post combustion of exhaust gases

Retort furnace NRA 300/09 H2 for heat treatment under hydrogen

H2 Version for Operation with Flammable Process Gases

When a flammable process gas like hydrogen is used, the retort furnace is additionally equipped with the required safety technology. Only certified and industry proven safety sensors are used. The furnace is controlled by a fail-safe PLC control system (S7- 300F/safety controller).

  • Supply of flammable process gas at controlled overpressure of 50 mbar relative
  • Certified safety concept
  • Process control H3700 with PLC controls and graphic touch panel for data input
  • Redundant gas inlet valves for hydrogen
  • Monitored pre-pressures of all process gases
  • Bypass for safe flushing of furnace chamber with inert gas
  • Torch for thermal post combustion of exhaust gases
  • Emergency flood container for purging the furnace in case of failore
Available Model Number: NRA 17/.., NRA 25/.., NRA 50/.., NRA 75/.., NRA 150/., NRA 200/.., NRA 300/.., NRA 400/.., NRA 500/.., NRA 700/.., NRA 1000/..   Bottom Loading Retort Furnaces up to 1100 °C
Bottom loading retort furnace LBR 300/11 H2 with safety technology for operation with Hydrogen as process gas Gas management system at bottom loading retort furnace LBR 300/11 H2

The bottom loading retort furnaces of the LBR series are suitable for production processes that are carried out in protective/reaction gas atmosphere. With regard to the basic performance data, these models are constructed like the SR models. Their size and design with electro-hydraulically driven lifting bottom make it easier to load heavy duties. The retort furnaces are available in different sizes and designs.

Basic version (all models)

  • Tmax 650 °C, 950 °C or 1100 °C
  • Frame-mounted housing with stainless steel sheets
  • Charging from the front
  • Electro-hydraulically driven furnace bottom
  • Gas supply system for a non-flammable protective gas or reaction gas with flow meter and solenoid valve
  • Temperature control designed as furnace chamber control
  • Connection possibility for an optional vacuum pump (cold evacuation or operation up to 600 °C under vacuum)
  • Defined application within the constraints of the operating instructions
  • NTLog Basic for Nabertherm controllers: recording of process data with USB flash drive
  • Additional equipment, H2 version and IDB version see models NR and NRA
Cold-Wall Retort Furnaces up to 2400 °C or up to 3000 °C  
Retort furnace SVHT 9/24-W with tungsten heating
Graphite heating module Cylindrical retort with tungsten heating Cooling water distribution Compared with the VHT models (page 64 ff), the retort furnaces of the SVHT product line offer improved performance data with regard to achievable vacuum and maximum temperature. Due to the design as pit-type furnace with tungsten heating, processes up to max. 2400 °C even in high vacuum can be implemented with retort furnaces of the SVHT..-W product line. Retort furnaces of the SVHT..-GR product line with graphite heating, also in pit-type design, can be operated in an inert gas atmosphere even up to max. 3000 °C.
  • Standard sizes with a furnace chamber of 2 or 9 liters
  • Designed as pit-type furnace, charged from above
  • Frame construction with inserted sheets of textured stainless steel
  • Dual shell water-cooled stainless steel container
  • Manual operation of process gas and vacuum functions
  • Manual gas supply for non-combustible process gas
  • A step in front of the retort furnace for an ergonomic charging height
  • Retort lid with gas-charged shock absorbers
  • Controls and switchgear as well as gas supply integrated in furnace housing
  • Defined application within the constraints of the operating instructions
  • Further standard product characteristics see description for standard design of VHT models

Heating Options

SVHT ..-GR

  • Applicable for processes:
    • Under protective or reaction gases or in the vacuum up to 2200 °C under consideration of relevant max. temperature limits
    • Under inert gas argon up to 3000 °C
  • Max. vacuum up to 10-4 mbar depending on the type of pump used
  • Heating: graphite heating elements in cylindrical arrangement
  • Insulation: graphite felt insulation
  • Temperature measurement by means of an optical pyrometer

SVHT ..-W

  • Applicable for processes under protective or reaction gases or in vacuum up to 2400 °C
  • Max. vacuum up to 10-5 mbar depending on the type of pump used
  • Heating: cylindrical tungsten heating module
  • Insulation: tungsten and molybdenum radiant plates
  • Optical temperature measurement with pyrometer
  • Additional equipment such as automatic process gas control or design for the operation with flammable gases incl. safety system see VHT models
Available Model Number: SVHT 2/24-W, SVHT 9/24-W, SVHT 2/30-GR, SVHT 9/30-GR   Cold-Wall Retort Furnaces up to 2400 °C  
Retort furnace VHT 500/22-GR H2 with CFC-process box and extension package for operation under hydrogen
Graphite heating chamber Molybdenum or tungsten heating chamber Molybdenumdisilicide heater and fiber insulation The compact retort furnaces of the VHT product line are available as electrically heated chamber furnaces with graphite, molybdenum, tungsten or MoSi2 heating. A wide variety of heating designs as well as a complete range of accessories provide for optimal retort furnace configurations even for sophisticated applications. The vacuum-tight retort allows heat treatment processes either in protective and reaction gas atmospheres or in a vacuum, subject to the individual furnace specs to 10-5 mbar. The basic furnace is suited for operation with non-flammable protective or reactive gases or under vacuum. The H2 version provides for operation under hydrogen or other flammable gases. Key of the specification up is a certified safety package providing for a safe operation at all times and triggers an appropriate emergency program in case of failure.

Alternative Heating Specifications

In general the following variants are available wit respect to the process requirements:

VHT ../..-GR with Graphite Insulation and Heating

  • Suitable for processes under protective and reaction gases or under vacuum
  • Tmax 1800 °C , 2200 °C or 2400 °C (VHT 40/.. - VHT 100/..)
  • Max. vacuum up to 10-4 mbar depending on pump type used
  • Graphite felt insulation

VHT ../..-MO or VHT ../..-W with Molybdenum or Tungsten Heating

  • Suitable for high-purity processes under protective and reaction gases or under high vacuum
  • Tmax 1200 °C, 1600 °C or 1800 °C (see table)
  • Max. vacuum up to 10-5 mbar depending on pump type used
  • Insulation made of molybdenum rsp. tungsten radiation sheets

VHT ../..-KE with Fiber Insulation and Heating through Molybdenum Disilicide Heating Elements

  • Suitable for processes under protective and reaction gases, in air or under vacuum
  • Tmax 1800 °C
  • Max. vacuum up to 10-2 mbar (up to 1300 °C) depending on pump type
  • Insulation made of high purity aluminum oxide fiber
  • Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
Schematic presentation of a cold-wall retort furnace with additional equipment 1 Retort 2 Heating 3 Insulation 4 Gas management system 5 Vacuum pump 6 Cooling water distribution 7 Controls 8 Integrated switchgear 9 Heating transformer 10 Charging frame inside the inner process chamber Retort furnace VHT 8/16‑MO with automation package
Retort furnace VHT 100/16‑MO with automation package

Basic version

  • Standard furnace sizes 8 - 500 liters
  • Water-cooled retort made of stainless steel
  • Frame made of stable steel profiles, easy to service due to easily removable stainless steel panels
  • Housing of the VHT 8 model on castors for easy repositioning of furnace
  • Cooling water manifold with manual tap, automatic flow monitoring, open-loop cooling water system
  • Adjustable cooling water circuits with flowmeter and temperature indicator and overtemperature protection
  • Switchgear and controller integrated in furnace housing
  • Process control with controller P470
  • Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2
  • Manual operation of the process gas and vacuum functions
  • Manual gas supply for one process gas (N2 , Ar or non-flammable forming gas) with adjustable flow
  • Bypass with manual valve for rapid filling or flooding of furnace chamber
  • Manual gas outlet with overflow valve (20 mbar relative) for over-pressure operation
  • Single-stage rotary vane pump with ball valve for pre-evacuating and heat treatment in a rough vacuum to 5 mbar
  • Pressure gauge for visual pressure monitoring
  • Defined application within the constraints of the operating instructions
Retort furnace VHT 40/22-GR with motor-driven lift door and front frame for connection to a glovebox
Heat treatment of copper bars under hydrogen in retort furnace VHT 8/16-MO Thermocouple, type S with automatic pull-out device for precise control results in the low temperature range Turbo-molecular pump

Additional equipment housing/heater

  • Housing, optionally divisible, for passing through narrow door frames (VHT 8)
  • Lift door
  • Individual heating concepts

Additional equipment gas management system

  • Manual gas supply for second process gas (N2, Ar or non-flammable forming gas) with adjustable flow and bypass
  • Mass flow controller for alternating volume flow and generation of gas mixtures with second process gas (only with automation package)
  • Inner process box made of molybdenum, tungsten, graphite or CFC, especially recommended for debinding processes. The box is installed in the furnace with direct gas inlet and outlet and provides for better temperature uniformity. Generated exhaust gases will be directly lead out the inner process chamber during debinding. The change of gas inlet pathes after debinding results in a clean process gas atmosphere during sintering.

Additional equipment vacuum

  • Two-stage rotary vane pump with ball valve for pre-evacuating and heat-treating in a fine vacuum (up to 10-2 mbar) incl. electronic pressure sensor
  • Turbo molecular pump with slide valve for pre-evacuation and for heat treatment in a high vacuum (up to 10-5 mbar) including electronic pressure sensor and booster pump
  • Other vacuum pumps on request
  • Partial pressure operation: protective gas flushing at controlled underpressure (only with automation package)

Additional equipment cooling

  • Heat exchanger with closed-loop cooling water circuit
  • Direct cooling

Additional equipment for controls and documentation

  • Charge thermocouple with display
  • Temperature measurement at 2200 °C models with pyrometer in the upper temperature range and thermocouple, type C with automatic pull-out device for precise control results in the low temperature range (VHT 40/..-GR and larger)
  • Automation package with process control H3700
    • 12" graphic touch panel
    • Input of all process data like temperatures, heating rates, gas injection, vacuum at the touch panel
    • Display of all process-relevant data on a process control diagram
    • Automatic gas supply for one process gas (N2, argon or non-flammable forming gas) with adjustable flow
    • Bypass for flooding and filling the chamber with process gas controlled by the program
    • Automatic pre- and post programs, including leak test for safe furnace operation
    • Automatic gas outlet with bellows valve and overflow valve (20 mbar relative) for over-pressure operation
    • Transducer for absolute and relative pressure
  • Process control and documentation via VCD software package or Nabertherm Control Center (NCC) for monitoring, documentation and control

Single-stage rotary vane pump for heat treatment in a rough vacuum to 5 mbar

Two-stage rotary vane pump for heat treatment in a vacuum to 10-2 mbar

Graphite inner process chamber incl. charge holder

Molybdenum inner process chamber incl. six charge supports

Process Box for Debinding in Inert Gas

Certain processes require charges to be debinded in non-flammable protective or reactive gases. For these processes we fundamentally recommend a hot-wall retort furnace (see models NR .. or SR ..). These retort furnaces can ensure that the formation of condensation will be avoided as throughly as possible.

If there is no way to avoid the escape of small amounts of residual binder during the process, even in the VHT furnace, the retort furnace should be designed to meet this contingency.

The furnace chamber is equipped with an additional process box that has a direct outlet to the exhaust gas torch through which the exhaust gas can be directly vented. This system enables a substantial reduction in the amount of furnace chamber contamination caused by the exhaust gases generated during debinding.

Depending on the exhaust gas composition the exhaust gas line can be designed to include various options.

  • Exhaust gas torch for burning off the exhaust gas
  • Condensation trap for separating out binding agents
  • Exhaust gas post-treatment, depending on the process, via exhaust gas washer
  • Heated exhaust gas outlet to avoid condensation deposits in the exhaust gas line
Available Model Number: VHT 8/..., VHT 25/.., VHT 40/.., VHT 70/., VHT 100/.., VHT 250/.., VHT 500/.. ,
Retort furnace VHT 100/15-KE H2 with fiber insulation and extension package for operation under hydrogen, 1400 °C Retort furnace VHT 40/16-MO H2 with hydrogen extension package and process box
Gas management system

H2 Version for Operation with Hydrogen or other Reaction Gases

In the H2 version the retort furnaces can be operated under hydrogen or other reaction gases. For these applications, the systems are additionally equipped with the required safety technology. Only certified and industry proven safety sensors are used. The retort furnaces are controlled by a fail-safe PLC control system (S7-300F/safety controller).
  • Certified safety concept
  • Automation package
  • Redundant gas inlet valves for hydrogen
  • Monitored pre-pressures of all process gases
  • Bypass for safe purging of furnace chamber with inert gas
  • Pressure-monitored emergency flooding with automated solenoid valve opening
  • Electrically heated or gas-fired exhaust gas torch for H2 post combustion
  • Atmospheric operation: H2-purging of retort starting from room temperature at controlled over pressure (50 mbar relative)

Additional equipment

  • Partial pressure operation: H2 flushing at underpressure in the retort starting from 750 °C furnace chamber temperature
  • Inner process hood in the retort for debinding under hydrogen
  • Process control and documentation via Nabertherm Control Center (NCC) for monitoring, documentation and control
      Catalytic and Thermal Post Combustion Systems, Exhaust Gas Washer     Temperature Uniformity and System Accuracy     Process Control and Documentation     Product-Videos

Bogie Hearth Furnaces

Pit-Type and Top-Loading Furnaces

Melting Furnaces

Salt-Bath Furnaces

Protective Gas/Vacuum Furnaces

Clean Room Furnaces

High-Temperature Furnaces

Chamber Furnaces

Ovens/Chamber Dryers

Tube Furnaces/Rotary Tube Furnaces

Laboratory Furnaces

Continuous furnaces

Rotary hearth furnaces

Furnace Plants

Quench and Temper Plants

AMS 2750 E/NADCAP

Controller Tutorials

Nippon Denshoku

Nippon Denshoku


ผู้ผลิตเครื่องวัดสีแบบอัตโนมัติสำหรับอุตสาหกรรมปิโตรเลียม ปิโตรเคมี น้ำมันพืช พลาสติค โพลิเมอร์ ผลิตภัณฑ์อาหาร กระจก เครื่องสำอาง อุปกรณ์อิเลคทรอนิคส์ กระดาษ สิ่งพิมพ์ ชิ้นงานโลหะ เฟอร์นิเจอร์ เครื่องวัดค่าความมันเงา (Gloss Meter)  เครื่องวัดค่าความขุ่น (Turbidity) เครื่องวัดคุณภาพน้ำดื่ม น้ำเสีย เครื่องทดสอบสำหรับงานวิจัยทางแสง สี การส่องสว่าง เป็นต้น

Spectrophotometers & Color Difference Meters
เครื่องวัดค่าสีแบบอัตโนมัติ

 Spectrophotometers & color difference meters

Our desk-top type instruments with basic color measuring functions are shown in this catalogue?(12 models in total). Those consist of color meters, color difference meters, whiteness meters, transmission color meter, petroleum color meter and Hazen color number measuring instrument, etc.



Handy Spectrophotometers & Color Meters
เครื่องวัดค่าสีแบบพกพา

 

Handy spectrophotometers & color meters Our portable type compact and light-weight instruments are shown in this catalogue?(3 models in total). Those consist of color checker, color checker/densitometer and spectrophotometers.




Software

ซอฟแวร์ประมวลผล

Software Two types of software for color management by personal computer are available for associated use with our color measuring instruments. You can enjoy sophisticated data display, color analysis and data transfer to personal computer using the software.



Photometer & Spectrophotometer
เครื่องวัดค่าสีแบบกำหนดมุมในการวัดได้

 

Photometer & spectrophotometer Our two variable angle color measuring instruments are shown in this catalogue. Those are used to measure reflectance or color differences of samples with particular reflection characteristics, and illuminating and light-receiving angles can be adjusted.





Haze Meters

เครื่องวัดค่าความใสหรือความขุ่นของแผ่นฟิล์มพลาสติค

 

Haze meters These instruments are based on the product test method of transparent plastic material. There are one all-in-one type that meets different sizes of samples and two separate types (consisting of a measuring unit and a separated optical unit) as shown in this catalogue.



Gloss meters & Reflectometers
เครื่องวัดค่าความมันเงาของกระดาษ โลหะ งานพิมพ์ งานเคลือบ เป็นต้น

 

Gloss meters & reflectometers These instruments are used to measure glossiness on the surfaces of papers, metals, resins and coatings, etc. Seven different models are shown in this catalogue, including gloss meters, reflectometers and densitometer.



Turbidimeters & Color Meters
เครื่องวัดค่าความขุ่นของน้ำ เครื่องวัดขนาดและจำนวนสิ่งสกปรก เครื่องวัดขนาดอนุภาคในน้ำดื่ม

 

???????(??????) Turbidity and color of clean water and wastewater can be measured by these instruments that are very effective for water quality management. Eight different models are shown in this catalogue, including turbidimeter, color meter, water analyzers, drainage analyzer, particle counters, etc.





เครื่องวัดค่าสีแบบสเปคโตรโฟโตมิเตอร์ – Spectrophotometer

SD 7000เครื่องวัดค่าสีแบบสเปคโตรโฟโตมิเตอร์ – Spectrophotometer

 

SD 7000 Using this high precision spectrophotometer, measurement of samples by reflectance and transmittance is possible at the spectral range 380nm~780nm with 5nm output interval.

Spectrophotometer



SE 6000เครื่องวัดค่าสีแบบสเปคโตรโฟโตมิเตอร์ความละเอียดสูง – Spectrophotometer

 

SE 6000 Both reflectance and transmittance measurements are possible using this one unit, with availability to measure various types of solid, liquid, powder, pellet and film sample in the range of 380nm to 780nm at 10nm output wavelength interval.

Optical Fiber Type Spectrophotometer



SE 6000+OFเครื่องวัดค่าสีแบบสเปคโตรโฟโตมิเตอร์พร้อมเซ็นเซอร์สัมผัสแบบสออพติคไฟเบอร์

 

SE 6000+OF By applying a pen type head to your samples, it will become possible to measure even the samples with complicated shapes including Automobile components, Dental material and skin, Convexo-concave samples and etc…

 

 

 



เครื่องวัดค่าสีแบบสเปคโตรโฟโตมิเตอร์สำหรับพื้นที่ขนาดเล็ก – Microscopic Area Spectrophotometer

VSS 400

VSS 400 This model is spectrophotometer for very small area which makes it possible to measure the spectral reflection rate and spectral transmittance by magnifying the microscopic area through a microscope.

Color Meter



ZE 6000
เครื่องวัดค่าสีแบบอัตโนมัติสำหรับตัวอย่างของแข็ง ของเหลวและผง

 ZE 6000 Both reflectance and transmittance measurements are possible using this one unit, with availability to measure various types of solid, liquid, powder, pellet and film samples.

Spectrophotometric Whiteness & Color Meter



PF 7000
เครื่องวัดค่าความขาวของกระดาษ เครื่องวัดค่าความขาวสว่างของกระดาษ

 

PF-7000 This is a spectro-photometric colormeter which has been developed along with the establishment of ISO 2470 “Whiteness Test Method for Paper and Paper Board by Diffused Lightning method (ISO Brightness)”, and conforms to the characteristic B of this standard.

Compact color & whiteness meter



NW-11
เครื่องวัดค่าสี ค่าความขาวแบบอัตโนมัติ

 

NW-11 This is a portable type compact color/whiteness meter with rather light weight.

Transmission Color Meter



  TZ 6000
เครื่องวัดค่าสีแบบอัตโนมัติสำหรับตัวอย่างของเหลว น้ำมัน และฟิล์ม

TZ 6000 This model is special for measuring the transmission color for the film and liquid.

Color, Oil & Haze Measuring Instrument



COH 400
เครื่องวัดค่าสี ค่าความขุ่นแบบอัตโนมัติสำหรับตัวอย่างเรซิน กระจก ของเหลวในหน่วย ASTM, Saybolt, Hazen (APHA) และ Gardner

 

COH 400 Using this COH 400,it is possible to measure transmitted color and haze (turbidity) of resin, glass and liquid samples, as well as total light transmittance, diffuse transmittance, parallel transmittance, Saybolt color, ASTM color, Hazen color number (APHA) and Gardner color. Color Meter for Petroleum Products



OME 2000เครื่องวัดค่าสีแบบอัตโนมัติสำหรับตัวอย่างน้ำมันปิโตรเลียมในหน่วย ASTM, Saybolt, Hazen (APHA) และ Gardner

 

OME 2000 This is a color measuring instrument for petroleum products used to measure liquid colors of petroleum oil and greases.

Portable Color Meter for Petroleum Products




OIL 1
เครื่องวัดค่าสีอัตโนมัติแบบพกพาสำหรับตัวอย่างน้ำมันปิโตรเลียมในหน่วย ASTM, Saybolt, Hazen (APHA) และ Gardner

OIL 1 This OIL 1 is a handy type colormeter, so you can measure anywhere so simply colors of petroleum products such as Saybolt color, ASTM color, Gardner color and Hazen color number (APHA).

Long Pathlength Transmission Spectrophotometer



ASA 1เครื่องวัดค่าสีแบบอัตโนมัติสำหรับตัวอย่างถาดพลาสติค

ASA 1 Using this ASA 1, it is possible to measure plastic-molding board of colorless near hi

 



 

Color Checker – เครื่องวัดค่าสีอัตโนมัติแบบพกพา

NR-11A

NR-11A NR-11A is light compact and portable Handy Color Meter.

Color Checker/Densitometer



NR-11B

NR-11B NR-11B is upgrade Color and Density meter of NR-11A

Spectrophotometer

 



NF 333

NF 333 This is a handy type simplified spectrophotometric color difference meter, and it makes it possible to measure both color and density by one unit.

 



Color Management Software – ซอฟแวร์ประมวลผล

Color Mate 5

Color Mate 5

Color Mate 5 is a software product for color management that enables to receive, display, analyze and manage color data by linking up with color measuring equipment of Nippon Denshoku Industries.

Color Management Software



Color Mate Pro
Color Mate Pro

Color Mate Pro is a new software product for color management with the screen layout function.

 

 

Variable Angle Photometer –



เครื่องวัดค่าสีแบบกำหนดมุมในการวัดได้

GC 5000L

GC 5000L This instrument is used to measure reflected or transmitted distribution of light that is emitted from liquid crystal displays, light fixtures, advertising displays, etc.

Variable angle spectrophotometer



GC 5000

GC 5000 For color difference measurement, it is significant to know a sample’s color distribution, which varies depending on light recieving angles, for the purpose of analyzing the nature of an object color.

 

Spectral Haze Meter – เครื่องวัดค่าความขุ่นแบบอัตโนมัติ สำหรับตัวอย่างแผ่นฟิล์ม พลาสติค ไวนิล กระจก แผ่นกรองแสง แผ่นฟิล์ม เป็นต้น



SH 7000

SH 7000 SH 7000 is a spectral haze meter that enables to simultaneously measure color values, spectral data, haze etc. Measurable in the wave length range of 380 to 780nm at 5nm intervals. Best choice for evaluation of high performance resin, optical films, glass, liquid, etc.

 



NDH 7000
เครื่องวัดค่าการส่องผ่านของแสงแบบอัตโนมัติ สำหรับตัวอย่างแผ่นฟิล์ม พลาสติค ไวนิล กระจก แผ่นกรองแสง แผ่นฟิล์ม เป็นต้น

 

NDH 7000

This model will be most appropriate for measurements of plastic, film, vinyl, or glass in the terms of haze (turbidity), total light transmittance, diffuse transmittance, parallel transmittance and Turb (turbidity mg / l) for the purpose of quality control.

Haze Meter



NDH 7000SP
เครื่องวัดค่าการส่องผ่านของแสงแบบอัตโนมัติสำหรับตัวอย่างแผ่นฟิล์ม พลาสติค

NDH 7000SP

NDH 7000SP is a haze meter that enables to measure haze, total light transmittance, diffuse transmittance, parallel transmittance and turbidity based on various industrial standards for plastic products (ISO 13468, ISO 14782 and ASTM D1003).

Haze Meter



NDH 2000N
เครื่องวัดค่าการส่องผ่านของแสงแบบอัตโนมัติ สำหรับตัวอย่างแผ่นฟิล์ม พลาสติค

NDH 2000N

NDH 2000N is a haze meter that is based on various industrial standards for plastic products, such as “Haze measurement for plastic/transparent material” (JIS K7136 & ISO 14782) and “Total light transmittance measurement for plastic/transparent material” (JIS K7361 & ISO 13468), etc.



 

Gloss Meter – เครื่องวัดค่าความมันเงาของกระดาษ ชิ้นงานโลหะ พลาสติค ไวนิล กระจก เป็นต้น

VG 7000เครื่องวัดค่าความมันเงาแบบตั้งโต๊ะ

VG 7000 This gloss meter is suitable for quality management for paper, metal plate, plastics, vinyl and glass which have gloss.

Handy type Gloss Meters



PG-II/IIMเครื่องวัดค่าความมันเงาแบบพกพา

PG-II/IIM Compact, light-weight, battery-operated and simple operation.

Direct Measuring Mirror Reflectometer



MG-I 400เครื่องวัดค่าความมันเงา การสะท้อนของกระจกรถยนต์

MG-I 400 MG-I 400 is a mirror reflectometer of direct measuring method that is based on the “Reflectance direct measuring method” for “Automotive mirrors (ISO 5740)”. Indirect Measuring Mirror Reflectometer




MG-II 400เครื่องวัดค่าความมันเงา การสะท้อนของกระจกรถยนต์

MG-II 400 MG-II 400 is a mirror reflectometer of indirect measuring method that is based on the “Reflectance indirect measuring method” for “Automotive mirrors (ISO 5740)”.

Microscopic Area Color Meter/Reflectometer



VSR 400

VSR 400

This model has been developed for the purpose of measuring the reflecton density of small area (say, gloss measurement of plating in the lead frame industries) regarding various types of electronic components, lead frames (lead wires), connectors, pattern plating of printed circuit boards, etc.

Densitometer



ND-11
เครื่องวัดค่าความหนาแน่นสี (Color Densitometer)

ND-11 This ND-11 is a handy type densitometer (reflection density meter) that is most appropriate for color density management by reflectance for electronic apparatuses, precision instruments, metals and building material, etc



Turbidimeter/Color Meter
เครื่องวัดค่าความขุ่นของน้ำดื่ม

WA 6000

WA 6000 Using this instrument, you can measure both turbidity and chromaticity of tap water in a moment time.

Auto Sampler for WA 6000



WA 2050S

WA 6000 This is an optional accessory to be used with WA 6000 or WA 2000N, which enables your measurements automatized and laborsaving.

Portable Water Analyzer





WA 1

WA 1 This is a portable type instrument for measuring water turbidity, coloration, residual chlorine and transparency.

High-sensitivity Turbidimeter/Particle Counter



NP 6000T

NP 6000T Capability of turbidity measurement and particle counting at the same time is most appropriate to meet the guide line.

Process Type High-sensitivity Turbidimeter/Particle Counter





NP 6000V

NP 6000V Capability of turbidity measurement and particle counting a is most Appropriate to meet the guide line.

Process Type Turbidimeter/Color Meter




WQA 6000

WQA 6000 This is an automatic measuring instrument to continuously monitor both turbidity and coloration based on the tap water test method under the water works law (in Japan).

Drainage Analyzer (for Coloration and Contaminated Color of Drainage)



NDR 2000

NDR 2000 NDR 2000 is an instrument that is used to control drainage color according to the regulations of local governments.

Process Type Drainage Analyzer (for Coloration and Contaminated Color of Drainage)




NDR System V

NDR System V This model is used for continuous monitoring of coloration, turbidity and chromaticity of factory liquid waste and waste water from households.

 

Normalab

Normalab

ผู้นำเครื่องมือวิจัยและเครื่องมือทดสอบผลิตภัณฑ์ปิโตรเลียม ปิโตรเคมี เชื้อเพลิง น้ำมันหล่อลื่น น้ำมันเครื่องบินอากาศยาน
ไบโอดีเซล ก๊าซโซฮอลล์ จาระบี น้ำมันหม้อแปลง สารเคมี แวกซ์ ยางมะตอย สารลดแรงตึงผิว สารเติมแต่ง เป็นต้น

เครื่องมือทดสอบแบ่งออกเป็นหมวดหมู่ดังต่อไปนี้

  • เครื่องมือทดสอบคุณสมบัติการติดไฟ การวาบไฟ การลุกไหม้ของน้ำมันและวัสดุติดไฟ(Flammability / Flash Point / Fire Point)
  • เครื่องมือทดสอบการระเหยของน้ำมัน ค่าความดันไอ (Volatility / Vapor Pressure / Distillation)
  • เครื่องมือทดสอบค่าความหนืดของน้ำมัน (Viscosity)
  • เครื่องมือทดสอบคุณสมบัติการไหลที่อุณหภูมิต่ำ จุดไหลเท จุดขุ่นมัว จุดเยือกแข็งของน้ำมัน (Cold Flow Properties)
  • เครื่องมือทดสอบน้ำมันหล่อลื่นและจาระบี (Lubricants and Grease)
  • เครื่องมือทดสอบยางมะตอย แวกซ์ ไข (Bitumen & Waxes)
  • เครื่องมือทดสอบน้ำมันเชื้อเพลิง น้ำมันเบนซิน น้ำมันดีเซล ไบโอดีเซล ก๊าซโซฮอลล์ (Fuel Analysis)
  • เครื่องมือทดสอบก๊าซหุงต้ม ก๊าซปิโตรเลียมเหลว (LPG Analysis)
  • เครื่องวัดสีน้ำมันปิโตเลียมและของเหลว (Color Analysis)
  • เครื่องมือทดสอบน้ำมันดิบ (Crude Oil Analysis)
  • เครื่องมือทดสอบความสะอาดของเชื้อเพลิง การปนเปลื้อนของน้ำมัน (Fuel Cleanliness)
  • อุปกรณ์เก็บ ตัก ตวง ตัวอย่างเพื่อนำมาทดสอบ (Sampling)
  • เครื่องแก้วสำหรับการทดสอบทางด้านปิโตรเลียมทุกชนิด (Petroleum Glassware & Accessories)
  • อุปกรณ์สอบเทียบ และน้ำยามาตรฐานสำหรับการสอบเทียบ (Calibration & CRM)
  • เทอร์โมมิเตอร์ตามมาตรฐานการทดสอบทุกชนิด (Thermometers)


ผลิตภัณฑ์ที่น่าสนใจในแต่ละหมวดเครื่องมือ

เครื่องมือทดสอบคุณสมบัติการติดไฟ การวาบไฟ การลุกไหม้ของน้ำมันและวัสดุติดไฟ (Flammability / Flash Point / Fire Point)

http://www.normalab.com/images/bullet_clair.gif  ABEL FLASH POINT TESTER – AUTOMATIC
http://www.normalab.com/images/bullet_clair.gif  ABEL FLASH POINT TESTER – MANUAL
http://www.normalab.com/images/bullet_clair.gif  CLEVELAND FLASH POINT – HALF AUTOMATED
http://www.normalab.com/images/bullet_clair.gif  CLEVELAND FLASH POINT – MANUAL
http://www.normalab.com/images/bullet_clair.gif  CLEVELAND FLASH POINT TESTER – AUTOMATIC
http://www.normalab.com/images/bullet_clair.gif  LUCHAIRE FLASH POINT – HALF AUTOMATED
http://www.normalab.com/images/bullet_clair.gif  LUCHAIRE FLASH POINT – MANUAL
http://www.normalab.com/images/bullet_clair.gif  LUCHAIRE FLASH POINT TESTER – AUTOMATIC –
http://www.normalab.com/images/bullet_clair.gif  PENSKY MARTENS FLASH POINT – MANUAL
http://www.normalab.com/images/bullet_clair.gif  PENSKY-MARTENS FLASH POINT – AUTOMATIC
http://www.normalab.com/images/bullet_clair.gif  PENSKY-MARTENS FLASH POINT – HALF AUTOMATED
http://www.normalab.com/images/bullet_clair.gif  SMALL VOLUME CLOSED CUP FLASH POINT TESTER – AUTOMATIC RAMP
http://www.normalab.com/images/bullet_clair.gif  SMALL VOLUME CLOSED CUP TESTER – MANUAL
http://www.normalab.com/images/bullet_clair.gif  SMOKE POINT OF KEROSINE AND AVIATION TURBINE FUEL
http://www.normalab.com/images/bullet_clair.gif  TAG CLOSED CUP FLASH POINT TESTER – AUTOMATIC

http://www.normalab.com/upload/D93%20NPM%20221.jpg

Semi-Automatic Pensky Martens Flash Point Tester, ASTM D93
Download
http://www.normalab.com/images/spacer_1x3_white.gif
Download D93_Pensky_Martens_NPM221_220_120 english.pdf

http://www.normalab.com/upload/D3828%20NPV%20310.jpg

Small Cup Flash Point Tester, ASTM D3828
Download
http://www.normalab.com/images/spacer_1x3_white.gif
Download D3828_Small_cup_flash_point_NPV_220_310.pdf

http://www.normalab.com/upload/IP%20170%20NAB%20440.jpg

Automatic Abel Flash Point Tester, IP170
Download
http://www.normalab.com/images/spacer_1x3_white.gif
Download IP170_NAB440.pdf

http://www.normalab.com/upload/NCL%20440%20PAsseur%20Web.jpg

Automatic Cleveland Open Cup Flash Point Tester with Auto Sample Changer, ASTM D92
Download
http://www.normalab.com/images/spacer_1x3_white.gif
Download D92_NCL440_automatic_Cleveland.pdf

http://dksh.micrologic.com.au/research/Normalab/normalab-2013.jpg
Automatic Pensky Martens Closed Cup Flash Point Tester, ASTM D93

เครื่องมือทดสอบการระเหยของน้ำมัน ค่าความดันไอ ค่าการกลั่น (Volatility / Vapor Pressure / Distillation)

http://www.normalab.com/images/bullet_clair.gif  AUTOMATIC ATMOSPHERIC DISTILLATION OF PETROLEUM PRODUCTS – MODEL NDI 450 –
http://www.normalab.com/images/bullet_clair.gif  DISTILLATION AT ATMOSPHERIC PRESSURE – HALF-AUTOMATED MODEL – ASTM D 86 –
http://www.normalab.com/images/bullet_clair.gif  DISTILLATION AT ATMOSPHERIC PRESSURE – MANUAL – ASTM D 86 –
http://www.normalab.com/images/bullet_clair.gif  DISTILLATION AT REDUCED PRESSURE
http://www.normalab.com/images/bullet_clair.gif  Reid Vapor pressure – mini method
http://www.normalab.com/images/bullet_clair.gif  “REID” VAPOUR PRESSURE OF PETROLEUM PRODUCTS
http://dksh.micrologic.com.au/research/Normalab/normalab-2013.jpghttp://ts4.mm.bing.net/th?id=HN.608000750212089846&w=137&h=142&c=7&rs=1&pid=1.7

Automatic Distillation Analyzer, ASTM D86
Download
http://www.normalab.com/images/spacer_1x3_white.gif
Download D86_NDI450_automatic distillation.pdf
 

เครื่องมือทดสอบค่าความหนืดของน้ำมัน (Viscosity)

http://www.normalab.com/images/bullet_clair.gif  CONSTANT TEMPERATURE VISCOSITY BATH
http://www.normalab.com/images/bullet_clair.gif  ENGLER VISCOMETER
http://www.normalab.com/images/bullet_clair.gif  KINEMATIC VISCOSITY OF TRANSPARENT AND OPAQUE LIQUIDS – TV BATHS
http://www.normalab.com/images/bullet_clair.gif  REDWOOD VISCOMETER
http://www.normalab.com/images/bullet_clair.gif  SAYBOLT VISCOSITY
http://www.normalab.com/images/bullet_clair.gif  VISCOMETER TUBE WASHER
http://www.normalab.com/images/bullet_clair.gif  VISCOMETER TUBES WITH CALIBRATION CERTIFICATE

http://www.normalab.com/upload/NVS210%20198%20pix.jpghttp://www.normalab.com/upload/D445%20ALV%20110.jpg
Viscosity Bath and Viscometer Tube Cleaner, ASTM D445

เครื่องมือทดสอบคุณสมบัติการไหลที่อุณหภูมิต่ำ จุดไหลเท จุดขุ่นมัว จุดเยือกแข็งของน้ำมัน (Cold Flow Properties)

http://www.normalab.com/images/bullet_clair.gif  CLOUD AND POUR POINT – AUTOMATED
http://www.normalab.com/images/bullet_clair.gif  CLOUD AND POUR POINT – CABINET
http://www.normalab.com/images/bullet_clair.gif  CLOUD AND POUR POINT – MANUAL BATH
http://www.normalab.com/images/bullet_clair.gif  COLD FILTER PLUGGING POINT – AUTOMATIC
http://www.normalab.com/images/bullet_clair.gif  COLD FILTER PLUGGING POINT – MANUAL BATH
http://www.normalab.com/images/bullet_clair.gif  FREEZING POINT OF AQUEOUS ANTIFREEZE SOLUTION
http://www.normalab.com/images/bullet_clair.gif  FREEZING POINT OF AVIATION FUELS

 

http://www.normalab.com/upload/941592.jpg

Cloud & Pour Point Tester, ASTM D2500, D97
Download
http://www.normalab.com/images/spacer_1x3_white.gif
Download D97_CPP_CLASSIC_and_CPP_BASIC.pdf

http://www.normalab.com/upload/D97%20NTE%20450.jpg

Automated Cloud & Pour Point Tester, ASTM D2500, D97
Download
http://www.normalab.com/images/spacer_1x3_white.gif
Download D97_CP_and_PP_NTE450.pdf

http://www.normalab.com/upload/NTL450.jpg

Automated Cold Filter Plugging Point (CFPP), ASTM D6371
Download
http://www.normalab.com/images/spacer_1x3_white.gif
Download D6371_NTL450_automated_CFPP.pdf

เครื่องมือทดสอบน้ำมันหล่อลื่นและจาระบี (Lubricants and Grease)

http://www.normalab.com/images/bullet_clair.gif  AIR RELEASE VALUE – IMPINGER METHOD
http://www.normalab.com/images/bullet_clair.gif  DIELECTRIC BREAKDOWN VOLTAGE OF INSULATING FLUIDS
http://www.normalab.com/images/bullet_clair.gif  FOAMING CHARACTERISTICS OF LUBRICATING OILS
http://www.normalab.com/images/bullet_clair.gif  HIGH TEMPERATURE FOAMING CHARACTERISTICS OF LUBRICATING OILS
http://www.normalab.com/images/bullet_clair.gif  HIGH TEMPERATURE FOAMING CHARACTERISTICS OF LUBRICATING OILS
http://www.normalab.com/images/bullet_clair.gif  OXIDATION STABILITY OF STEAM TURBINE OIL & MINERAL INSULATING OILS BY ROTATING TEST CYLINDER
http://www.normalab.com/images/bullet_clair.gif  OXIDATION STABILITY OF STEAM TURBINE OIL BY ROTATING TEST CYLINDER
http://www.normalab.com/images/bullet_clair.gif  WATER SEPARABILITY OF PETROLEUM OILS AND SYNTHETIC FLUIDS – HALF AUTOMATED
 
 

http://www.normalab.com/upload/REF%209416298.jpg

Oxidation Stability Tester (RPVOT/RBOT), ASTM D2112, D2272
Download
http://www.normalab.com/images/spacer_1x3_white.gif
 
Download   D2112_oxidation_stability_of_steam_turbine_oil.pdf

http://www.normalab.com/upload/REF%209416432.jpg
http://www.normalab.com/upload/REF%209416432.jpg

Foaming Tester, ASTM D892+Diffuser Washer
Download
http://www.normalab.com/images/spacer_1x3_white.gif
Download D892_high_temperature_foaming.pdf

http://www.normalab.com/upload/ASTM-D3427.jpg

Air Release Value Tester, ASTM D3427
Download
http://www.normalab.com/images/spacer_1x3_white.gif
Download D3427_arv_classic_impinger.pdf

http://www.normalab.com/upload/ASTMD1401.jpg

Water Separability / Demulsibility Tester, ASTM D1401
Download
http://www.normalab.com/images/spacer_1x3_white.gif
Download D1401DEM CLASSIC942545Leaflet09revamt.pdf

http://www.normalab.com/upload/OTS100AF2.jpg

Dielectric Breakdown, ASTM D877
Download
http://www.normalab.com/images/spacer_1x3_white.gif
Download   D877_dielectric_breakdown.pdf

เครื่องมือทดสอบยางมะตอย แวกซ์ ไข (Bitumen & Waxes)

http://www.normalab.com/images/bullet_clair.gif  BREAKING POINT OF BITUMEN – MANUAL MODEL
http://www.normalab.com/images/bullet_clair.gif  DENSITY OF SEMI-SOLID BITUMOUS MATERIALS
http://www.normalab.com/images/bullet_clair.gif  DUCTILITY OF BITUMINOUS PRODUCTS
http://www.normalab.com/images/bullet_clair.gif  EFFECTS OF HEAT AND AIR ON A MOVING FILM OF ASPHALT – ROLLING THIN FILM TEST
http://www.normalab.com/images/bullet_clair.gif  MANUAL SOFTENING POINT OF BITUMEN TESTER – RING & BALL METHOD –
http://www.normalab.com/images/bullet_clair.gif  OIL CONTENT OF PETROLEUM WAXES
http://www.normalab.com/images/bullet_clair.gif  PARTICLE POLARITY OF BITUMEN EMULSIONS
http://www.normalab.com/images/bullet_clair.gif  PENETRATION OF LUBRICATING GREASE – GREASE WORKER –
http://www.normalab.com/images/bullet_clair.gif  PENETRATION VALUE DETERMINATION – AUTOMATIC MODEL – BITUMINOUS MATERIALS –
http://www.normalab.com/images/bullet_clair.gif  PENETRATION VALUE DETERMINATION – AUTOMATIC MODEL – GREASES –
http://www.normalab.com/images/bullet_clair.gif  PENETRATION VALUE DETERMINATION – AUTOMATIC MODEL – GREASES BY GREASE WORKER –
http://www.normalab.com/images/bullet_clair.gif  PENETRATION VALUE DETERMINATION – AUTOMATIC MODEL – PETROLATUM –
http://www.normalab.com/images/bullet_clair.gif  PENETRATION VALUE DETERMINATION – AUTOMATIC MODEL – PETROLEUM WAXES –
http://www.normalab.com/images/bullet_clair.gif  PENETROMETER – MANUAL MODEL – BITUMINOUS MATERIALS –
http://www.normalab.com/images/bullet_clair.gif  PENETROMETER – MANUAL MODEL – GREASES –
http://www.normalab.com/images/bullet_clair.gif  PENETROMETER – MANUAL MODEL – GREASES BY GREASE WORKER –
http://www.normalab.com/images/bullet_clair.gif  PENETROMETER – MANUAL MODEL – PETROLATUM –
http://www.normalab.com/images/bullet_clair.gif  PENETROMETER – MANUAL MODEL – WAXES –
http://www.normalab.com/images/bullet_clair.gif  ROTATING CYLINDER AGEING TEST FOR BITUMEN
http://www.normalab.com/images/bullet_clair.gif  SOFTENING POINT OF BITUMEN TESTER – RING AND BALL METHOD
http://www.normalab.com/images/bullet_clair.gif  SOLVENT EXTRACTABLES OF PETROLEUM WAXES

 


Automatic Penetrometer, ASTM D6, D217

 

เครื่องมือทดสอบน้ำมันเชื้อเพลิง น้ำมันเบนซิน น้ำมันดีเซล ไบโอดีเซล ก๊าซโซฮอลล์ (Fuel Analysis)

http://www.normalab.com/images/bullet_clair.gif  ANILINE POINT AND MIXED ANILINE POINT OF PETROLEUM PRODUCTS AND HYDROCARBON SOLVENTS
http://www.normalab.com/images/bullet_clair.gif  API GRAVITY OF CRUDE PETROLEUM AND PETROLEUM PRODUCTS – ASTM D 1217 –
http://www.normalab.com/images/bullet_clair.gif  API GRAVITY OF CRUDE PETROLEUM AND PETROLEUM PRODUCTS – ASTM D 1298 –
http://www.normalab.com/images/bullet_clair.gif  API GRAVITY OF CRUDE PETROLEUM AND PETROLEUM PRODUCTS – ASTM D 1480 –
http://www.normalab.com/images/bullet_clair.gif  API GRAVITY OF CRUDE PETROLEUM AND PETROLEUM PRODUCTS – ASTM D 287 –
http://www.normalab.com/images/bullet_clair.gif  API GRAVITY OF CRUDE PETROLEUM AND PETROLEUM PRODUCTS – ASTM D 941 –
http://www.normalab.com/images/bullet_clair.gif  ASPHALTENES IN CRUDE PETROLEUM AND PETROLEUM PRODUCTS (HEPTANE INSOLUBLES)
http://www.normalab.com/images/bullet_clair.gif  Automatic Reference Fuel Blending Unit
http://www.normalab.com/images/bullet_clair.gif  BIO FUEL ANALYSIS
http://www.normalab.com/images/bullet_clair.gif  COPPER CORROSION FROM PETROLEUM PRODUCTS
http://www.normalab.com/images/bullet_clair.gif  ELECTRICAL CONDUCTIVITY OF AVIATION AND DISTILLATE FUELS
http://www.normalab.com/images/bullet_clair.gif  FALEX 400
http://www.normalab.com/images/bullet_clair.gif  HYDROCARBON TYPE IN LIQUID PETROLEUM PRODUCTS BY FLUORESCENT INDICATOR ADSORPTION METHOD
http://www.normalab.com/images/bullet_clair.gif  REFERENCE – CHECK FUEL BLENDING FOR OCTANE AND CETANE MEASUREMENT
http://www.normalab.com/images/bullet_clair.gif  REFERENCE – CHECK FUEL BLENDING FOR OCTANE AND CETANE MEASUREMENT
http://www.normalab.com/images/bullet_clair.gif  REFERENCE – CHECK FUEL BLENDING FOR OCTANE AND CETANE MEASUREMENT
http://www.normalab.com/images/bullet_clair.gif  SULPHUR IN CONTENT BY THE WICKBOLD COMBUSTION METHOD

http://www.technologylinks.com.pk/Images/Scientific/NormaLab/FuelAnalysis/40500.jpg
ANILINE POINT AND MIXED ANILINE POINT OF PETROLEUM PRODUCTS AND HYDROCARBON SOLVENTS

http://www.normalab.com/upload/24472.jpg

ASPHALTENES IN CRUDE PETROLEUM AND PETROLEUM PRODUCTS (HEPTANE INSOLUBLES), IP143
Download
http://www.normalab.com/images/spacer_1x3_white.gif
Download IP143_Aphtalenes_in_crude_petroleum.pdf

http://www.normalab.com/upload/REF_941600.jpg

HYDROCARBON TYPE IN LIQUID PETROLEUM PRODUCTS BY FLUORESCENT INDICATOR ADSORPTION METHOD,
ASTM D1319
Download
http://www.normalab.com/images/spacer_1x3_white.gif
Download D1319_FIA_classic.pdf

http://www.normalab.com/upload/REF%20NABLEND.jpg

Automatic Reference Fuel Blending Unit, ASTM D613
Download

Download D613_Nablenb88xx.pdf
http://www.normalab.com/images/spacer_1x3_white.gif

เครื่องมือทดสอบก๊าซหุงต้ม ก๊าซปิโตรเลียมเหลว (LPG Analysis)
http://www.normalab.com/images/bullet_clair.gif  DENSITY OF LIGHT HYDROCARBONS

เครื่องวัดสีน้ำมันปิโตเลียมและของเหลว (Color Analysis)

http://www.normalab.com/images/bullet_clair.gif  ASTM COLOR OF PETROLEUM PRODUCTS – MANUAL
http://www.normalab.com/images/bullet_clair.gif  SAYBOLT COLOR OF PETROLEUM PRODUCTS

เครื่องมือทดสอบน้ำมันดิบ (Crude Oil Analysis)

http://www.normalab.com/images/bullet_clair.gif  PRECIPITATION NUMBER OF LUBRICATING OIL – WATER & SEDIMENTS – CENTRIFUGE METHOD
http://www.normalab.com/images/bullet_clair.gif  PRECIPITATION NUMBER OF FUEL OILS – WATER & SEDIMENTS – CENTRIFUGE METHOD
http://www.normalab.com/images/bullet_clair.gif  PRECIPITATION NUMBER OF OIL – PENTANE AND TOLUENE INSOLUBLES – CENTRIFUGE METHOD
http://www.normalab.com/images/bullet_clair.gif  PRECIPITATION NUMBER OF OIL – SEDIMENTS – CENTRIFUGE METHOD
http://www.normalab.com/images/bullet_clair.gif  SALT IN CRUDE OIL – ELECTRONIC METHOD
http://www.normalab.com/images/bullet_clair.gif  WATER IN PETROLEUM PRODUCTS & BITUMINOUS MATERIALS BY DISTILLATION
http://www.normalab.com/images/bullet_clair.gif  WATER SEPARABILITY OF LUBRICATING OILS – CENTRIFUGE METHOD

 

http://ts4.mm.bing.net/th?id=HN.608000750212089846&w=137&h=142&c=7&rs=1&pid=1.7
Heatable Petroleum Centrifuge Model NCP Tech, ASTM D96, D893, D1796, D2273, D 2709,
D2711, D4007

 

เครื่องมือทดสอบความสะอาดของเชื้อเพลิง การปนเปลื้อนของน้ำมัน (Fuel Cleanliness)

http://www.normalab.com/images/bullet_clair.gif  ASH FROM LUBRICATING OILS
http://www.normalab.com/images/bullet_clair.gif  ASH FROM PETROLEUM PRODUCTS
http://www.normalab.com/images/bullet_clair.gif  CONRADSON CARBON RESIDUE OF PETROLEUM PRODUCTS
http://www.normalab.com/images/bullet_clair.gif  EXISTENT GUM IN FUELS BY JET EVAPORATION
http://www.normalab.com/images/bullet_clair.gif  FILTER BLOCKING TENDENCY OF DISTILLATE FUEL OILS – AUTOMATIC
http://www.normalab.com/images/bullet_clair.gif  HYDROLYTIC STABILITY OF HYDRAULIC FLUIDS
http://www.normalab.com/images/bullet_clair.gif  MICRO CARBON CONRADSON RESIDUE – MODEL NMC 210
http://www.normalab.com/images/bullet_clair.gif  MICRO CARBON CONRADSON RESIDUE – MODEL NMC 440
http://www.normalab.com/images/bullet_clair.gif  OXIDATION CHARACTERISTICS OF INHIBITED MINERAL OILS
http://www.normalab.com/images/bullet_clair.gif  OXIDATION CHARACTERISTICS OF PETROLEUM FUELS
http://www.normalab.com/images/bullet_clair.gif  OXIDATION CHARACTERISTICS OF VARIOUS OILS
http://www.normalab.com/images/bullet_clair.gif  OXIDATION STABILITY OF GASOLINES – AUTOMATED
http://www.normalab.com/images/bullet_clair.gif  OXIDATION STABILITY OF GASOLINES – MANUAL BATH
http://www.normalab.com/images/bullet_clair.gif  OXIDATION STABILITY OF GASOLINES IN FINISHED FORM – AUTOMATED
http://www.normalab.com/images/bullet_clair.gif  OXIDATION STABILITY OF GASOLINES IN FINISHED FORM – MANUAL BATH
http://www.normalab.com/images/bullet_clair.gif  SEDIMENT IN CRUDE AND FUEL OILS BY EXTRACTION METHOD

http://www.normalab.com/upload/NMC210.jpg http://www.gecil.com/g1data/s133/pgs0/45/tpl4/img/TN/124027310630900002-TR-0200-0000.jpg

 

MICRO CARBON CONRADSON RESIDUE – MODEL NMC 210, ASTM D4530
Download
http://www.normalab.com/images/spacer_1x3_white.gif
Download   D4530_NMC210_carbon_residue.pdf

http://www.normalab.com/upload/npi442.jpghttp://www.normalab.com/upload/REF%2040900.jpg

OXIDATION STABILITY OF GASOLINES – AUTOMATED, ASTM D525
Download
http://www.normalab.com/images/spacer_1x3_white.gif
Download   D525_NPI_440_NPI_442_potential_gums.pdf

http://www.normalab.com/upload/941623_1.jpg

OXIDATION CHARACTERISTICS OF VARIOUS OILS
Download
http://www.normalab.com/images/spacer_1x3_white.gif
Download   D943_TOST_CLASSIC.pdf

http://www.normalab.com/upload/941303.JPG

EXISTENT GUM IN FUELS BY JET EVAPORATION, ASTM D381
Download
http://www.normalab.com/images/spacer_1x3_white.gif
Download   D381_Jet_classic_existent_gums.pdf

อุปกรณ์เก็บ ตัก ตวง ตัวอย่างเพื่อนำมาทดสอบ (Sampling)

http://www.normalab.com/images/bullet_clair.gif  BRASS SAMPLING BOTTLES
http://www.normalab.com/images/bullet_clair.gif  SAMPLING OF LPG

เครื่องแก้วสำหรับการทดสอบทางด้านปิโตรเลียมทุกชนิด (Petroleum Glassware & Accessories)
อุปกรณ์สอบเทียบ และน้ำยามาตรฐานสำหรับการสอบเทียบ (Calibration & CRM)
เทอร์โมมิเตอร์ตามมาตรฐานการทดสอบทุกชนิด (Thermometers)


Novomatics

Novomatics

A picture containing icon

Description automatically generated

ผู้ผลิตเครื่องมือทดสอบสำหรับหมึกพิมพ์ เรซิน โพลิเมอร์ วานิช สำหรับงานวิจัยและควบคุมคุณภาพการพิมพ์แบบต่าง ๆ เช่น เครื่องทดสอบ Tack ของหมึกพิมพ์ เครื่องทดสอบ Water Balance และ Tack ในเครื่องเดียวกัน เครื่องทดสอบ Vanish Cooker แบบอัตโนมัติ เครื่องทดสอบความขุ่นและการเปลี่ยนแปลงเฟสของ Surfactants เครื่องทดสอบจุดขุ่นมัว (Cloud Point) ของเรซินหมึกพิมพ์ เครื่องทดสอบการดูดซึมน้ำของ Offset Ink, Lithographic Ink เครื่องทดสอบค่าการละลายของเรซินหมึกพิมพ์ / โพลิเมอร์ ด้วยหลักการ Cloud Point เครื่องทดสอบค่าความหนืดของ Vanishes

 

A picture containing indoor, white

Description automatically generated 

The new LithoTack II – เครื่องทดสอบ Water Balance และ Tack ในเครื่องเดียวกัน

The new LithoTack II is two laboratory instruments in one. On the one hand the LithoTack is a simply to use precision tack measuring instrument on the other the LithoTack II determines water balance behavior of thin ink film under practice relevant conditions. ASTMInk Emulsification TestingInk Surface InteractionWater BalanceWater Pick UpWet Tack

AlphaTackPlus

New AlphaTack Plus - เครื่องทดสอบ Tack ของหมึกพิมพ์

The AlphaTack Plus instrument allows quick tack determination of printing inks with a high degree of accuracy and reproducibility. Due to its closely controlled test conditions the AlphaTack Plus methodology offers significant advantages over the usual tack testing methods. The AlphaTack Plus provides a problem-solving approach to measuring pure tack (QC), ink length, tack stability vs. time, vs. temperature, vs. lineforce and offers a practical and consistent solution to commonly encountered problems of splitting ink films. ASTMTackTack MeasurementWet Tack

A picture containing text, device, printer

Description automatically generated

Thermotronic III/200 – เครื่องทดสอบ Vanish Cooker แบบอัตโนมัติ

The Thermotronic 200 is an automatic varnish cooker to prepare varnish samples independent of individual operator skills.Even high resin contents do not effect the quality of the varnish due to the powerful stirring motor and the use of a magnetic stirring bar of high volume and weight. A special test tube with a round bottom is used in order to avoid residual material in the test tube. The filling weight of the test tube is 200 grams.

In order to characterize the quality of resins, a solution of the resin must be prepared. The quality of the solution mainly depends on the parameters: the quality of the solvent & the consistency of the preparation  Varnish CookerVarnish Preparation

Turbi4

Turbitronic II – เครื่องทดสอบความขุ่นและการเปลี่ยนแปลงเฟสของ Surfactants

Surface active agents like surfactants are generally showing a specific turbidity behaviour. The classic method to determine turbidity is by visual observation, but the visual method is inaccurate and time consuming. For such applications the development of the turbidity analyzer Turbitronic II is a fundamental improvement regarding accuracy, reproducibility, efficiency and cost savings. In addition to this, severe errors in case of unknown phenomena like for instance dragging turbidity or opacity, can be avoided by automatic turbidity measurements. Clear pointCloud pointDIN/EN 1890ISO 0607Phase Transition

CTIII_new4 Kopie

Chemotronic III (ASTM D6038) – เครื่องทดสอบจุดขุ่นมัว (Cloud Point) ของเรซินหมึกพิมพ์

The cloud point temperature is a characteristic value in the quality control of synthetic resins or printing inks. Deviations in cloud point can lead to sedimentation the varnish, differences in drying speed, loss of gloss and tack stability. The cloud point is the temperature at which a resin begins to precipitate in the liquid phase.The automatic cloud point test method introduced here, has been approved by a great number of resin manufacturers worldwide as a standard method for production setting and quality control of printing ink resins. ASTM D6038cloud point testingink resinprecipitation temperature

LTIV

Lithotronic IV – เครื่องทดสอบการดูดซึมน้ำของ Offset Ink, Lithographic Ink

Quick waterbalance testing of offset inks with Lithotronic IV - A good ink-water balance is important for high quality printing on lithographic offset printing presses. In order to be able to predict the performance on the press, the water absorbency of lithographic inks must be tested.

The Lithotronic IV is the first device to determine the water balance performance of offset inks and fount solutionswith 1% accuracy. The instrument is equipped with automatic gap adjustment (known from upper class rheometers) and a ceramic dosing system. Temperature, shear-rate and fountain solution content are exactly regulated and are corresponding to the conditions on fast running printing presses. The modern software allows you a quick and safe data evaluation. Thus is testing and optimizing of your products already possible before the operation on the printing press. Ink emulsification testingink surface interactionwater balancewater pick upwet tack

A picture containing text

Description automatically generated

Chemotronic Cool – เครื่องทดสอบค่าการละลายของเรซินหมึกพิมพ์ / โพลิเมอร์ ด้วยหลักการ Cloud Point

The Chemotronic Cool is designed for measuring the solubility of resins (and polymer blends) by means of cloud point determination over an extended temperature range.

The standard Chemotronic III can determine cloud points in the range of +50° to +220° C only, which is generally sufficient for quality control applications. However, in order to use it as a research instrument or to expand the measurable range a wider temperature range and extra features are advantageous. ASTM D6038cloud point testingink resinprecipitation temperature

TTIII_new Kopie

Thermotronic III – เครื่องทดสอบค่าความหนืดของ Vanishes

The Thermotronic III is a rheological tool to standardize varnish     preparation and viscosity measurements in research and industry. In order to produce varnishes of consistent structure and quality, Novomatics has developed an automatic device for quick and reproducible preparation of test-oil-based varnishes prior to the viscosity measurements.  The objective was to eliminate the possibility of errors due to individual influences in the dissolving phase in order to improve the accuracy and reproducibility of viscosity measurements. Solvency and compatibility deviations have been minimized by use of highly specific test oils. varnish cookervarnish preparation

Omnitek

Omnitek

ผู้ผลิตเครื่องวัดค่าความหนืดแบบใช้ตัวอย่างน้อยสำหรับน้ำมันดีเซล น้ำมันหล่อลื่น น้ำมันหล่อลื่นใช้แล้ว สารเคมีและอื่น ๆ แบบอัตโนมัติตามมาตรฐาน ASTM D445, D7279 เครื่องวัดค่าความหนืดแบบมาตรฐานพร้อมระบบล้างในตัว และเครื่องวัดค่าความชื้นของเม็ดพลาสติค

S-flow 1200 S-flow®-3000 VI
เครื่องวัดค่าความหนืดแบบใช้ตัวอย่างน้อยสำหรับน้ำมันดีเซล น้ำมันหล่อลื่น การทำงานเป็นแบบอัตโนมัติ ระบบล้างแบบ Double Solvent (Automatic Viscometer acc. to ASTM D445, D7279)
Read more…
S-flow 1200 S-flow®- 1200
เครื่องวัดค่าความหนืดแบบใช้ตัวอย่างน้อยสำหรับน้ำมันดีเซล น้ำมันหล่อลื่น การทำงานเป็นแบบอัตโนมัติ ระบบล้างแบบ Double Solvent (Automatic Viscometer acc. to ASTM D445, D7279)
Read more…
S-flow 850 S-flow®- 850เครื่องวัดค่าความหนืดแบบใช้ตัวอย่างน้อยสำหรับน้ำมันดีเซล น้ำมันหล่อลื่น การทำงานเป็นแบบอัตโนมัติ Double Solvent (Semi – Automatic Viscometer acc. to ASTM D445, D7279)
Read more…
S-flow 400 S-flow®- 400
เครื่องวัดค่าความหนืดแบบใช้ตัวอย่างน้อยสำหรับน้ำมันดีเซล น้ำมันหล่อลื่น การทำงานเป็นแบบอัตโนมัติ แบบ Manual (Manual Viscometer acc. to ASTM D445, D7279)
Read more…

Remark:
Measuring times, results and specifications all comply with or exceed the requirements stated in ASTM D445, D7279, ISO 3104and related specifications for kinematic viscosity testing. Automatic Viscosity Index calculation according to ASTM D2270

U-VIsc 200 Fully Automatic Viscometer

http://www.omnitek.nl/pix/uvisc_tray.jpg
Download Catalog : U-VIsc Brochure http://www.omnitek.nl/pix/pdficon.gif

 

 

Features

The U-VIsc 200 combines several unique features, making it the instrument of choice in many applications, ranging from QC to R&D to used oil analysis. While offering full compliance with ASTM D445/446, the specially designed viscometer tubes cover an 100-foldrange, so a single tube can cover a range of 1-100, 2-200 mm2/s etc. The tubes are based on the well-known and proven Ubbelohde design. Through modification the main advantage of this design (accuracy) is maintained, but the main disadvantages (sample and solvent consumption, ease of use) negated. The modified tubes only require 8-12 ml. of sample and approx. 15-20 ml. of solvent for cleaning. Available with 1 or optional 2 solvent cleaning, the instrument measures kinematic viscosity between 0.5 and 5,000 mm2/s.

The instrument is compact, saving costly bench space. It is fitted with 2 independent baths, which each contain 2 100-fold viscometer tubes. Sophisticated temperature control ensures that measurements are carried out well within ASTM D445 requirements. Each bath features a 32-position sampling tray (16 samples per tube), allowing completely unattended operation. Depending on the viscosity of the sample, the instrument can process up to 40 samples per hour, satisfying even the needs of high volume commercial labs running several hundred samples per day. All measurement data is stored on the connected PC and can be exported directly to LIMS or spreadsheet software.

Measurement procedure

The user loads the sample tray with 32 samples (16 samples per tube) for each bath and enters the sample ID’s through the PC interface. After pressing start, the instrument will process these samples completely automatically. The following will describe briefly how this is performed. After start, the oil is sucked up into the viscometer and allowed to come up to the test temperature. When this has been reached, the oil will be allowed to travel down the viscometer. When it passes the thermal sensor which is integrated into the tube, the time measurement will start.

When the second sensor is passed, the time measurement is stopped. The result is presented on-screen and on the PC software or optionally on an external printer. Immediately upon completion of the measurement, the system starts a cleaning cycle by first draining the tube, performing the specified number of injections of solvent and finally drying the tube. The entire cycle time (meaning from the injection of a sample until the system is ready to process the next sample) ranges from 6-7 minutes, allowing for a capacity of approx. 10 samples per hour per tube, i.e. 40 samples per hour for the entire system.

Advantages

  • Autosampling enables fully unattended operation
  • 100-fold tube range eliminates the need to exchange tubes
  • Fully compliant with ASTM D445/D446, ISO3104/3105 and related specifications
  • Requires less sample (8-15 ml) than conventional viscometer
  • Reduced solvent consumption (up to 60% compared to conventional viscometers)
  • Automatic Viscosity Index calculation if baths are run at 40º and 100ºC
  • Extremely stable bath temperature (±0.005°C)
  • Compact, rugged design and built to last
  • Low maintenance

Specifications

Measuring range 0.5 – 5,000 cSt @ 40 ºC
Temperature range 25 – 110º C *
Temperature stability ±0.005ºC @ 40º C, ±0.015 @ 100º C
Sample volume 8-12 ml
Solvent consumption 12-15 ml per cycle
Sample throughput up to 40 samples per hour
Applicable standards ASTM D445, D446, 2270, ISO 3104 and 3105 and
related standards for kinematic viscosity
Dimensions 705 x 588 x 693mm. (l x w x h)
Viscometer type Modified Ubbelohde
Sensor type Thermistor
Communication RS-232C
  * For measurements around ambient an external chiller is required

 

Moisture analysers for plastics

เครื่องวัดค่าความชื้นของเม็ดพลาสติคแบบอัตโนมัติ (Moisture Meter)Designed for production applications : no chemicals !

AVM-3000
The AVM-3000 moisture analyser for plastics is a completely automated system offering advanced pc integration

  • Designed as a reliable, rugged alternative for Karl Fischer titration
  • Fully compliant with ISO specifications
  • Fully automatic measurement procedure
  • Reliable and repeatable results deep into the ppm-range
  • Cuts analysis costs considerably
  • Does NOT require highly qualified operators
  • Can be deployed in a production environment
  • Does not use any chemicals
  • Low maintenance
  • Significant reduction of secondary costs
  • Supports real time data export to pc or LIMS

http://www.omnitek.nl/pix/pdficon.gif AVM 3000 Brochure

Our analysers use the manometric method described in the International Standard ISO 15512 on moisture determination in polyamids.

Measurement procedure

Our moisture analysers utilize the manometricprinciple described in ISO 15512 as measuring technique. Using this technique, the pressureincrease caused by the evaporating water can be used to proportionally determine the moisture content of the sample.

In practice, the measuring procedure for the AVM-3000 is as follows :

  • Weigh a sample…
  • …insert it into the sample holder
  • …attach the holder to the instrument
  • …feed Sample ID and weight into the system
  • …press Start
  • walk away …

All this can be performed within 1-2 minutes. After the Start button has been pushed, no user attendance is required. The system performs the measurement automatically.

No chemicals whatsoever are used in the determination and the entire procedure is sosimple that it can be performed by productionpersonnel in stead of highly trained laboratory staff ! Ideal in situations where a laboratory is not available and where close monitoring of theproduction parameters is required.

The system evacuates the sample holder, creating a vacuum. This, combined with directheat applied by the oven that surrounds the sample, guarantees complete evaporation of thewater in the sample. The system monitors the resulting pressure increase and presents the user with the end result. A typical measurement takes 15-45 minutes to complete. The instrument measures from 10 ppm up to approx. 5 %.

Specifications

Measuring range: 10 ppm to approx. 5%
Non-linearity: <0.1% of the measuring range:
Long-term stability: error <0.1% per year
Display & Data entry: Clear touch-screen panel
Oven characteristics: 220°C (max.), 450VA
Temperature control: Advanced PID
Temperature stability: Better than ± 1°C
Operation: Manual or automatic
Requirements
Vacuum supply: Capable of pressures <100 Pa
Compressed air supply: 5-6 Bar
Analytical scales: Resolution 0.1 mg